Tip 1-3. Inspect ASSY Auger Motor operation
Check Point
Step 1
①
Disassemble ice Bucket which is in F room.
②
Disassemble 3 screws on the top.
Step 2 (Single product inspection)
①
Disassemble ice bucket which is in freezer.
②
Disassemble Auger Motor, inspect Motor
- Normal product GRY+BLK 3~4 Ω
- Failure part : Open & 0 Ω
Step 3
①
Disassemble the Main PBA Cover which is on
the back
②
Inspect Connector which is on right bottom
- Inspect CN70 No.3(RED)and CN73 No.9(PRK)
Inspect Auger Motor.
- 6/47 -