Tip 5-2. Inspect EVAP DEFROST BUILD
※ Do not off the power and operate self-diagnosis test on "TIP 5-1"
first.
Must check the forced defrost operation after defrosting repair.
Step 1
Press Display "Lighting"+ "Energy Saver" Key for 8
sec at the same time until "Dingdong" sound
appear.
※ When the Error occurs Measure it to
move TIP 5-1.
- When there is no ERROR, or DEFROST ERROR
Check Step2
Step 2
①
Disassemble EVAP COVER EVAP-FRE FRONT
& COVER Multi.
②
Melt right CONNECTOR part with STEAMER
and disassemble the COVER.
Step 3
①
Measure BROWN WIRE resistance.
- Normal part : 35~60 Ω
- Failure part : Open or 0 Ω
Replace it because of HEATER &
BIMETAL OPEN failure
Step 4
①
When freezing appears on DEFROST SENSOR
part, replace it
Step 5
①
Bottom and DEF-SENSOR part don't have
freezing and top center has freezing only.
-Location of DEF-SENSOR should move to
center pipe.
because it is SENSOR failure.
- 31/47 -
Defrost
Error
HEATER
& BIMETAL
DEF-SENSOR
MOVE
Next Page