WARNINGS
Storage system power on/off: The push-button on/off power switch on the
front panel of the storage system does not turn off the AC power. To remove
AC power from the storage system, you must unplug the AC power cord
from either the power supply or wall outlet.
Hazardous conditions—power supply: Hazardous voltage, current, and
energy levels are present inside the power supply enclosure. There are no
user-serviceable parts inside the power supply; servicing should only be done
by technically qualified personnel.
Hazardous conditions—devices and cables: Hazardous electrical
conditions may be present on power, telephone, and communication cables.
Turn off the storage system and disconnect telecommunications systems,
networks, modems, and the power cord attached to the storage system before
opening it. Failure to do so can result in personal injury or equipment
damage.
Avoid injury: Lifting the storage system chassis and attaching it to the rack
is a two-person job. If needed, use an appropriate lifting device. A fully
®
loaded Intel
(70 lbs.).
CAUTIONS
Temperature: The operating temperature of the storage system, when
installed in an equipment rack, must not go below 5° C (41° F) or rise above
35° C (95° F). Extreme fluctuations in temperature can cause a variety of
problems in the storage system.
Ventilation: The equipment rack must provide sufficient airflow to the front
of the storage system to maintain proper cooling. It must also include
ventilation sufficient to exhaust a maximum of 1900 BTUs per hour for a
fully loaded Intel
®
Intel
Storage System SSR316MJ2 Power Distribution Module
Storage System SSR316MJ2 weighs approximately 31.8 kg
®