Travel Limits; Closing Garage Door (Down Limit) - Genie 1035 Operation & Maintenance Manual

Belt/chain drive
Hide thumbs Also See for 1035:
Table of Contents

Advertisement

Programming Information

TRAVEL LIMITS

WARNING
!
Make sure doorway is in full view and clear of obstacles and
people to avoid injury or property damage.
DO NOT operate this unit from the wall control before LIMITS
are set. Severe damage to the opener could occur.
The carriage MUST be engaged to turnbuckle BEFORE setting
limits. See installation poster (if provided) or call Customer
Service at 1-800-35-GENIE or visit www.GenieCompany.com.
DO NOT set limits with Battery Backup attached. AC power
MUST be connected to the opener while setting limits for
proper operation.
NOTE: If turnbuckle has NOT been engaged to carriage, do so now.
Before setting limits: Con rm wall console red indicator
back light is ON. If not illuminated, See page 19 for troubleshooting.
Check STB LED's: Con rm both LED's are Illuminated solid. If not
Illuminated solid, see page 18 for troubleshooting.

Closing Garage Door (Down Limit)

NOTE:
Beginning with garage door in mid travel is recommended but not
necessary.
1. Lift door by hand until carriage engages the turnbuckle
on the chain/belt.
Lever must be UP
READ AND UNDERSTAND STEPS 2-5 BEFORE
PROCEEDING
2. Press and hold the down arrow button (–) for two
seconds or until the long LED comes on blue. (The round
LED stays o .)
Steady Blue
3. Release down arrow button (–) and the long LED will
begin ashing blue. (Round LED still o .)
Flashing Blue
6
AVERTISSEMENT
!
S'assurer que le passage de la porte est visible et dégagé, à
savoir sans obstacles ni personne a n d'éviter toute blessure
potentielle ou dommage matériel.
NE PAS utiliser cette unité avec la console murale avant
d'avoir réglé les LIMITES. L'ouvre-porte pourrait subir de
sérieux dommages.
La tendeur DOIT être engagée dans le chariot AVANT de
régler les limites. Voir le poster d'installation (si fourni) ou
appelez le service clientèle au 1-800-35-GENIE ou visitez le
site www.GenieCompany.com.
NE PAS xer de limites en mode batterie de secours.
L'alimentation CA DOIT être branchée sur l'ouvre-porte,
pendant le réglage des limites, pour assurer un bon
fonctionnement.
4. Press and hold the down arrow button (–) to begin
closing the garage door. When the garage door is fully
closed, release the down button (–). If it has gone too far
press and release the up button (+) to move the door
up slightly. The door can be moved up or down with the
arrow buttons. The door should rest tightly on the oor.
5. Press and release the program/set button—both LEDs
ash blue and then go o .
The DOWN (CLOSED) TRAVEL LIMIT IS NOW PROGRAMMED.
Flashing
Blue

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

203520362055303530557035 ... Show all

Table of Contents