Installation Instructions

Installing Room Air Conditioners

Proper installation of a room air conditioner helps ensure
trouble free operation of the unit. Improper installation of
this device can result in problems ranging from noisy
operation to property or equipment damage.
The following paragraphs provide general instructions
and information on installing an Amana Room Air
Conditioner. Detailed instructions, included with unit or
with a separately purchased mounting kit, should be
used to perform actual installation.
Before attempting to install unit:
· Carefully read all instructions pertaining to installation.
Make sure each step or procedure is understood and
any special considerations are taken into account.
· Assemble all tools and hardware needed to complete
installation. Some items may need to be purchased
locally. Make sure required tools and hardware are on
hand before starting.
· After deciding where to install unit, closely look the
location over, both inside and outside. Note any
potential obstacles or problems that might be
encountered. Choose a more suitable location if
necessary.

Electrical Requirements

!
WARNING
To avoid risk of personal injury or death due to
electrical shock:
· Electrical grounding is required on this device.
· DO NOT ground to gas line.
· If cold water pipe is interrupted by plastic,
nonmetallic gaskets, or other insulating (non
conducting) materials, DO NOT use it for ground.
· Check with a qualified electrician if you are not
sure this appliance is properly grounded.
· DO NOT modify plug on power cord. If plug does
not fit electrical outlet, have a proper outlet
installed by a qualified electrician.
· DO NOT have a fuse in the neutral or ground
circuit. A fuse in the neutral or ground circuit could
result in an electrical shock.
· DO NOT use an extension cord with this
appliance.
Observe all local codes and ordinances.

Grounding Instructions

For safety, air conditioner must be grounded. This air
conditioner has a power supply cord with a three-prong
grounding plug. To minimize possible electrical shock
hazards, the power cord must only be plugged into a
matching grounding wall receptacle in accordance with
the National Electrical Code (and any applicable local
codes and ordinances). If an appropriate grounding-type
wall receptacle is not available, it is the responsibility of
the consumer to have a properly grounded wall
receptacle installed by a qualified electrician.
If codes permit, and a separate grounding wire is used,
have a qualified electrician determine if grounding path is
adequate and uninterrupted by plastic, nonmetallic
gaskets, or other insulating (non conductive) materials.
Do not use an extension cord. If air conditioner power
cord cannot reach wall receptacle, have a qualified
electrician install an appropriate receptacle closer to unit.
Receptacle Wiring
Receptacle wiring must be of adequate size for unit.
Refer unit identification plate or Technical Sheet for exact
power requirements of unit. Minimum size of wiring,
based on power requirements, is:
Units up to 20 amps:
Units up to 30 amps:
Use copper wire only. It is consumer's responsibility to
provide proper and adequate receptacle wiring that
conforms to all applicable codes. All wiring should be
installed by a qualified electrician.

Electrical Connection

Electrical ground is required on this appliance.
Electrical Requirements
A separate circuit, serving only this appliance, MUST be
provided. Devices covered in this manual require a 60 Hz
supply. Refer to unit name plate or Technical Sheet for
exact voltage requirements.
7
12 gauge
10 gauge
RS4100004 Rev. 0