Amana Room Air Conditioner & Heat Pump Use And Care Manual
Amana Room Air Conditioner & Heat Pump Use And Care Manual

Amana Room Air Conditioner & Heat Pump Use And Care Manual

Hide thumbs Also See for Room Air Conditioner & Heat Pump:

Advertisement

Contents
Introduction .................................................................. 1
Safety Information ....................................................... 1
Normal Care and Maintenance .................................. 3
Installation Instructions ............................................... 5
Electrical Requirements .............................................. 5
General Instructions ................................................... 11
Operating Controls .................................................... 12
Before Calling Service .............................................. 13
When Service Is Required ........................................ 14
Any Questions? .......................................................... 14
Warranty ..................................................................... 18

Introduction

Room air conditioners cool, dehumidify, and filter air inside
your home. Heat pump and electric heat models offer both
heating and cooling. Opening sections of manual provide
general information for all room air conditioner models.
Operating Controls section describes operation of controls
for each model. After reading the opening sections, turn to
Operating Controls section and find the panel layout that
matches the model of your unit.
Read entire manual thoroughly before beginning installation
and operation of your new room air conditioner. Be sure you
have all necessary tools and materials on hand for the job.
Study illustrations to familiarize yourself with important
details of the installation process. Review manual for oper-
ating instructions.
Part. No. 120B
Room Air Conditioner & Heat Pump
NOTE
1. Mechanical experience is required to install air condi-
tioner.
2. Installation can take from 1 to 3 hours, depending on
installer's knowledge and skill.
3. If you encounter problems during installation, call our
consumer information line toll-free at 1-877-254-4729. If
your problem cannot be resolved by phone, contact an
authorized Amana
will be at your expense.

Safety Information

Be sure electrical service is adequate for chosen model of air
conditioner. Complete electrical rating for unit is found on
serial plate located behind front grille. Electrical outlet must
be close enough to unit for power cord to reach without strain.
Air conditioner should be the only appliance on individual
circuit.
For personal safety and to avoid possible damage to appli-
ance or home, observe all safety instructions highlighted by
symbol shown below.
RECOGNIZE THIS SYMBOL AS A
SAFETY PRECAUTION.
After installing unit, reread instructions to ensure each step
is complete and that all parts are fastened in place. For best
results and to minimize installation time, perform all proce-
dures in the order shown.

Use and Care Manual

®
brand servicer. Contact and service
©2006 Goodman Company, L.P.
®
Effective: November 2006

Advertisement

Table of Contents
loading

Summary of Contents for Amana Room Air Conditioner & Heat Pump

  • Page 1: Table Of Contents

    3. If you encounter problems during installation, call our consumer information line toll-free at 1-877-254-4729. If your problem cannot be resolved by phone, contact an ® authorized Amana brand servicer. Contact and service will be at your expense. Safety Information...
  • Page 2 OWNER'S PRODUCT IDENTIFICATION WARNING MODEL NUMBER To prevent heat related illness or death, do not use this device for unattended cooling SERIAL NUMBER of persons or animals unable to react to MANUFACTURING NUMBER product failure. Failure of unattended air conditioner may result in extreme heat in area intended for cooling, causing heat- Owner's Name related illness or death of persons or...
  • Page 3: Normal Care And Maintenance

    Unit Plug Receptacle Circuit Rating, Voltage Installation Type Required Breaker, Time Rating On Complete step-by-step installation instructions are furnished Delay Fuse Nameplate with your unit. These instructions will be found on a separate NEMA No. 5-15P NEMA No. 5-15R 125V-15AMP 115V page included with this manual or in the mounting kit assembly.
  • Page 4 Slide-out Chassis Removal from Outer Case Annual Inspection It is suggested that your unit be inspected by your dealer or See Figure H. servicer once a year. It is advisable to have the outer case removed and the unit thoroughly cleaned. 3.
  • Page 5: Installation Instructions

    Installation Air Conditioner Instructions Disconnect ALL power to unit before installing or servicing, making WARNING sure unit is plugged in only when instructions state it is safe to do so. Failure to follow instructions may cause property damage, personal injury or death. Question? Consumer information line toll-free 1-877-254-4729 CAUTION BEFORE YOU BEGIN...
  • Page 6: Installation Instructions

    Installation Instructions PARTS INCLUDED Window (A ppearance m ay vary) sash seal Left accordion panel Foam top window gasket mounting rail Right accordion panel V-support (2) Window locking Bolt (2) & nuts (2) bracket (2) Type A (6) Type B (4) Type C (7) Type D (6) Type E (6)
  • Page 7: Window Requirements

    Installation Instructions 3 REMOVE THE AIR CONDITIONER 1 WINDOW REQUIREMENTS FROM THE CASE • These instructions are for a standard double- hung window. You will need to modify them for Remove the 2 shipping screws (if present) other types of windows. from the back of the case and discard them.
  • Page 8 Installation Instructions PREPARE THE CASE INSTALL THE CASE IN THE WINDOW Install the top mounting rail with 4 type B screws from the inside of the case. Carefully slide the case into the window and center the case. Lower the window behind Insert the frames for the accordion panels the top mounting rail.
  • Page 9: Ins Tallation Ins Tructions

    Ins tallation Ins tructions INSTALL THE CASE INSTALL SUPPORT BRACKETS IN THE WINDOW (cont.) AND THE FOAM TOP WINDOW GA S K E T Adjust the leveling bolts and nuts against the outside wall so that the case has a slight tilt A ttach the s upport brackets with two to the outside.
  • Page 10 Ins tallation Ins tructions INS TALL THE AIR CONDITIONER INSTALL THE AIR CONDITIONER IN THE CASE IN THE CASE (cont.) Slide the air Pull the coiled power cord from its shipped conditioner into position in the air discharge area. Attach the case.
  • Page 11: General Operating Instructions

    To install, remove the unit chassis from the outer case. Insert General Operating Instructions the condensate drain cup through the recessed ½” hole on While operation of all units is similar, controls vary slightly the back center flange of the outer case. Once inserted, from model to model.
  • Page 12: Operating Controls

    Operating Controls COMFORT ZONE AND HEAT PUMP MODELS CIRCULAIRE Fan Control Temperature Control OFF – Completely shuts off the unit. To prevent blowing Rotate to the right, clockwise, for cooler termperatures or fuses, wait three minutes after turning the unit off before left, counter-clockwise, for warmer temperatures.
  • Page 13: Before Calling Service

    Before Calling Service WARNING Turn the fan control to the off position and remove the unit plug from the wall outlet before doing any inspection or maintenance work. Failure to do so may cause personal injury or death due to electrical shock. The following is a list of problems that are sometimes encountered when using a room air conditioner.
  • Page 14: When Service Is Required

    - please call: • An accurate description of problem. CONSUMER INFORMATION LINE • Complete model, serial, and manufacturing numbers AMANA TOLL FREE from serial plate. 1-877-254-4729 (U.S. only) • Proof of purchase (sales receipt) upon request. email us at: customerservice@goodmanmfg.com...
  • Page 15: Through-The-Wall Installation Instructions

    Thru-wall Installation Instructions ® for Amana brand Room Air Conditioner Introduction This instruction sheet provides guidelines for installing a 26" compact air conditioner through an outside wall. CAUTION Installing an air conditioner through a wall requires extensive carpentry and/or mason- ry experience.
  • Page 16: Masonry Construction

    Brick Veneer or Frame Wall Construction CAUTION See CAUTION under General Instructions. Cut or build In order to reinstall the chassis and re- rough opening large enough to allow a framed, finished attach the air conditioner front cover, the opening 17 3/4-inches high and 26 3/16-inches wide. When installed outercase must be square and case is properly positioned in opening, secure it to framing level from side to side.
  • Page 17 Installation in Wall When case is properly positioned in opening, use wood shims to fill any gaps between case and finished opening, Thicker Than 8 1/2-inches especially in area where case will be secured to opening. The side louvers in outer case provide ventilation to air con- Take care not to warp or distort case when installing ditioner compressor and fan motor and must not be shims.
  • Page 18: Warranty

    Part No. HI-120B ©2006 Goodman Company, L.P. Effective: November 2006...