3. Technical brief
Trickle charging
When the VBAT is below a certain value, 3.2V, a current generator take care of internal trickle charge
signal is active. The charging current is set to 50mA.
Parameter
Trickle current
Normal charging
When the VBAT voltage is within limits or the internal regulators are turned on, the current source for
trickle charging is turned off and all parts of the charging block are active. The charging method is
'CCCV'. (Constant Current Constant Voltage)
This charging method is used for Lithium chemistry battery packs. The CCCV method regulates the
charge current and the VBAT voltage. This charging method prevents the battery voltage to go above
the charge set in the CCCV algorithm. (Figure 3-5-8) shows the charging voltage(a) and charging
current change(b).
(a) Charging voltage
(b) Charging current
LGE Internal Use Only
Min
30
Table. 3-5-4. Trickle charging spec
Figure 3-5-8. CCCV charging method
- 66 -
Typ
Max
50
60
Copyright © 2009 LG Electronics. Inc. All right reserved.

Only for training and service purposes

Unit
mA