Operation

Before Startup
Mount loose parts delivered with appliance
prior to start-up.
Illustrations on Page 3
Illustration
Insert the steering rollers and lock them.
Illustration
Insert the transport wheels and lock
them.
Illustration
Pull out the clamp for the high-pressure
hose from the trigger gun (e.g. a small
screwdriver).
Illustration
Connect high pressure hose to trigger
gun.
Push the clamp in until it locks. Check
the secure connection by pulling on the
high-pressure hose.
Water supply
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Note: Impurities in the water can damage
the high-pressure pump and accessories.
For protection, the use of the KÄRCHER
water filter (optional accessory, order no.
4.730-059) is recommended.
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/tech-
nical data.
Use a fibre-reinforced water hose (not
included) with a standard coupling.
(Minimum diameter 1/2 inch (13 mm),
minimum length 7.5 m).
Screw the coupling element (supplied) to
the water connection on the appliance.
6 English
Push the water supply hose onto the
coupling unit, then connect it to the wa-
ter supply.
Start up
Caution
Dry runs lasting longer than two minutes
lead to damages to the high pressure
pump. If the appliance does not build up
pressure within two minutes, switch it off
and proceed as instructed in the Chapter
"Troubleshooting".
Connect the high pressure hose to the
high pressure connection of the appli-
ance.
Push the spray lance into the trigger
gun and fasten it by turning it through
90°.
Completely open the water tap.
Fully unroll power cable.
Insert the mains plug into the socket.
Turn on the appliance "I/ON".
Operation
Danger
The trigger gun is subjected to a recoil force
when the water jet is discharged. Make sure
that you have a firm footing and are also hold-
ing the trigger gun and spray lance firmly.
Unlock the lever on the trigger gun.
Pull on the lever of the trigger gun; the
device will switch on.
Note: Release the lever of the trigger gun;
the device will switch off again. High pres-
sure remains in the system.
Spray lance with high pressure nozzle
For normal cleaning tasks.
Not suitable for use with detergents.
Spray lance with Dirtblaster
For particularly dirty items or areas.
Not suitable for use with detergents.
Move the appliance
The appliance can be pulled by the
high-pressure hose during operation.
Caution
Only pull the appliance if the mains con-
necting cable is unwound.

Hide quick links: