General Information; Heat Pump Controller; Quick Reference Instructions; Selection Of The Operating Mode - Dimplex WPR 2006 Operating Instructions Manual

Heat pump controller
Table of Contents

Advertisement

Available languages

Available languages

1

1 General Information

For installation, operation and maintenance refer to the
installation and operating instructions. This device should only be
installed and repaired by a competent technician. Poorly carried
out repairs can endanger the safety of the user. According to
current regulations, the installation and operating instructions
must always be available and should be handed to the technician
working on the device for his/her information. Therefore, we
request that these installation and operating instructions be
passed on to the new tenant or owner when there is a change in
occupancy. Do not connect the device if it is visibly damaged. In
this event, ask the supplier for advice. Ensure that only original
spare parts are used to prevent consequential damage. All
environmentally-relevant requirements regarding the recovery,

2 Heat Pump Controller

The heat pump controller is essential for operation of air-to-
water, brine-to-water and water-to-water heat pumps. It
regulates a bivalent, monovalent or mono energy heating
system. It is delivered as a wall-mounted controller and carries
out the regulation of the heating system (radiators and circulation
pump).
Overview of functions
Convenient 6-button operation
Large and clear illuminated LC display with indicators for
operating status and service information
Dynamic menu navigation, customised for the configured
heat pump system

3 Quick Reference Instructions

3.1 Selection of the Operating Mode

Select the desired operating mode by repeatedly pressing the modus button.
Cooling
The system operates in cooling operation.
Summer
Domestic hot water heating and swimming pool water heating only. Antifreeze (frost protection) is ensured.
Auto
Programmed raising and lowering times are automatically activated.
Vacation
Temperature reduction and domestic hot water block for an adjustable time period.
Party
A programmed lowering of the heating characteristic curves is overridden.
2nd Heat Generator
Heat pump is blocked. Heat is generated by the 2nd heat generator.

3.2 Changing the Settings

Hold the MENU button depressed for several seconds
Select the desired menu item with the arrow buttons
(
and
)
Confirm by pressing the ENTER button (
Select the desired submenu item with the arrow buttons
(
and
)
E-2
recycling and disposal of materials and components should be
observed in accordance with the applicable standards.
Regulations and Safety Information!
Any adjustments to the settings within the device may only
be carried out by an authorised technician.
The heat pump controller should only be operated in dry
rooms with temperatures ranging between 0 °C and 35 °C.
Ensure that no condensation forms on the device.
To ensure that the antifreeze function of the heat pump
works properly, the heat pump controller must remain
connected to the power supply and the flow must be
maintained through the heat pump at all times.
Remote control interface with identical menu navigation
Return
operation based on external temperature, adjustable fixed-
setpoint or room temperature
Control of up to 2 heating circuits
Priority switching
– DHW preparation first
– Heating first
– Cooling
Control of a 2nd heat generator
(oil or gas boiler, or immersion heater)
Confirm with the ENTER button (
setting
Change the setting to the desired value with the arrow
buttons (
)
Confirm new value with the ENTER button (
the ESC button
temperature-controlled
regulation
) until cursor jumps to the
and
)
of
heating
) or revoke with