General Information; Heat Pump Manager - Dimplex WPM 2006 plus Operating Instructions Manual

Heat pump controller
Table of Contents

Advertisement

1 General Information

For installation, operation and maintenance refer to the
installation and operating instructions. This device should only be
installed and repaired by a competent technician. Poorly carried
out repairs can endanger the safety of the user. According to
current regulations, the installation and operating instructions
must always be available and should be handed to the technician
working on the device for his/her information. Therefore, we
request that these installation and operating instructions be
passed on to the new tenant or owner when there is a change in
occupancy. Do not connect the device if it is visibly damaged. In
this event, ask the supplier for advice. Ensure that only original
spare parts are used to prevent consequential damage. All
environmentally-relevant requirements regarding the recovery,

2 Heat Pump Manager

The heat pump manager is essential for operation of air-to-water,
brine-to-water and water-to-water heat pumps. It regulates a
bivalent, monovalent or mono energy heating system and
monitors the safety components in the refrigerating circuit. The
heat pump manager is either installed in the heat pump casing or
is delivered with the heat pump as a wall-mounted controller. It
carries out regulation of both the heating system (radiators and
circulation pump) and the heat source system.
Overview of functions
Convenient 6-button operation
Large and clear illuminated LC display with indicators for
operating status and service information
Conforms with utility company requirements
Dynamic menu navigation, customised for the configured
heat pump system
Remote control interface with identical menu navigation
Return
temperature-controlled
operation based on external temperature, adjustable fixed-
setpoint or room temperature
Control of up to 3 heating circuits
Priority switching
– Cooling first
– DHW preparation first
– Heating first
– Swimming pool
regulation
of
heating
recycling and disposal of materials and components should be
observed in accordance with the applicable standards.
Regulations and Safety Information!
Any adjustments to the settings within the device may only
be carried out by an authorised technician.
The heat pump manager should only be operated in dry
rooms with temperatures ranging between 0 °C and 35 °C.
Ensure that no condensation forms on the device.
To ensure that the antifreeze function of the heat pump
works properly, the heat pump manager must remain
connected to the power supply and the flow must be
maintained through the heat pump at all times.
Control of a 2nd heat generator
(oil or gas boiler, or immersion heater)
Control of a mixer for a 2nd heat generator (oil, gas, solid
fuel boiler, or regenerative heat source)
Special program for a 2nd heat generator to ensure
minimum runtimes (oil boiler) or minimum heating times
(main cylinder)
Control of a flange heater for targeted reheating of domestic
hot water with adjustable time programs, and for thermal
disinfection
Optional control of up to 5 circulating pumps
Defrost management system to minimise the energy
required for defrosting using variable, self-adjusting
defrosting cycle times
Compressor management system to ensure balanced
loading of the compressors for heat pumps with two
compressors
Operating hours counter for compressors, circulating
pumps, 2nd heat generator and flange heater
Keyboard block, child lock
Alarm memory with time and date
Interface for communication via PC with optional display of
heat pump parameters
Automatic program for targeted heat drying of screed floors
and saving the start and finish times
2