HP Integrity BL860c i2 Installation Manual page 14

Server blade
Hide thumbs Also See for Integrity BL860c i2:
Table of Contents

Advertisement

Online/activity LED (green)
Flashing regularly (1 Hz)
Flashing regularly (1 Hz)
Flashing irregularly
Flashing irregularly
Off
Off
Off
14
Installing the server blade into the enclosure
Fault/UID LED (amber/blue)
Amber, flashing regularly (1 Hz)
Off
Amber, flashing regularly (1 Hz)
Off
Steadily amber
Amber, flashing regularly (1 Hz)
Off
Interpretation
Do not remove the drive. Removing
a drive might terminate the current
operation and cause data loss. The
drive is part of an array that is
undergoing capacity expansion or
stripe migration, but a predictive
failure alert has been received for this
drive. To minimize the risk of data
loss, do not replace the drive until the
expansion or migration is complete.
Do not remove the drive. Removing
a drive might terminate the current
operation and cause data loss. The
drive is rebuilding, erasing, or it is part
of an array that is undergoing capacity
expansion or stripe migration.
The drive is active, but a predictive
failure alert has been received for this
drive. Replace the drive as soon as
possible.
The drive is active, and it is operating
normally.
A critical fault condition has been
identified for this drive, and the
controller has placed it offline. Replace
the drive as soon as possible.
A predictive failure alert has been
received for this drive. Replace the
drive as soon as possible.
The drive is offline, a spare, or not
configured as part of an array.

Advertisement