Air Cap Adjustment Valve
Use to control amount of air that passes
through air cap and over mixing chamber tip.
Airflow helps keep tip free of sprayed chemi-
cal. Too much air may distort spray pattern
and create overspread. Too little air will not
properly clean end of valving rod.
To OPEN valve, turn knob approximately 1/8
turn counterclockwise.
To CLOSE valve, turn knob fully clockwise.
Open
F
. 7: Air Valve Adjustment
IG
Felt Wiper
Adjust Felt Wiper
1. Use 5/16 in. open-end wrench to loosen
retainer slightly.
2. Slowly tighten it by hand until it seats
against rear packings in mixing chamber.
311320J
Close
3. Use 5/16 in. open-end wrench to tighten
retainer another half turn.
F
. 8: Felt Wiper
IG
Clean Felt Wiper
1. Insert nozzle of flush can into holes of felt
wiper.
2. Saturate felt with gun cleaner.
Operation Basics