CBS-2130XTS Dimensions & Utility Connections Rough-in Drawings-Continued
Rough-in CBS-2131XTS—Single station 1-gallon airpot version
Rough-in CBS-2132XTS—Dual station 1-gallon airpot version
Water Requirements CBS-2131XTS & CBA-2132XTS:
20-75 psig (138-517kPa) 1½gpm/(5.7lpm)
Water inlet fitting is a 3/8 inch male flare.
Brew Volume:
CBS-2131XTS & 2132XTS—3 liter version: Full Batch=3 liter
CBS-2131XTS & 2132XTS—1 gal version Full Batch=1 gal
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice

Utility Requirements

16
Drawing#1201.00013.00
Drawing#1201.00014.00
Inlet Water Temperature: Cold or Hot supply
Coffee Filter Size:
13"X5"– standard FETCO # F002
Electrical: See electrical configuration chart.
Temperature:
200°F (93°C) inside water tank (at sea level)
195°F (91°C) ± 5° at sprayhead