SLP98UH110V60C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
SLP98UH135V60D BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
icomfort Touch™ Communicating Thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- 35%, 60%, 80%, 100% (four-stage) with time delays in-between
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 450 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 450 cfm.
BLOWER DATA
35%
40%
767
861
738
825
708
789
655
731
602
673
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
1060
1245
1345
970
1145
1265
885
1025
1110
35%
40%
949
1033
879
957
808
881
748
817
687
753
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
1070
1260
1410
980
1115
1255
865
1020
1115
Page 44
Heating Input Range and Blower Volume - CFM
50%
60%
1049
1237
1000
1174
951
1112
883
1035
816
958
Blower Speed Selections
Second Stage Cool Speed - cfm
High
Low
(Default)
1545
1560
1395
1405
1250
1270
Heating Input Range and Blower Volume - CFM
50%
60%
1200
1367
1113
1269
1026
1172
956
1095
886
1019
Blower Speed Selections
Second Stage Cool Speed - cfm
High
Low
(Default)
1555
1565
1430
1445
1280
1290
70%
80%
90%
1424
1612
1800
1349
1524
1699
1274
1436
1597
1187
1339
1491
1101
1243
1386
Medium-
Medium
Low
High
1740
1930
1565
1775
1425
1610
70%
80%
90%
1534
1701
1868
1426
1582
1738
1317
1463
1608
1235
1374
1513
1152
1284
1417
Medium-
Medium
Low
High
1750
1970
1615
1805
1470
1650
100%
1988
1874
1759
1644
1528
High
(Default)
2125
1945
1770
100%
2035
1895
1754
1652
1550
High
(Default)
2190
1985
1805