Lennox SLP98UHV Installation Instructions Manual page 43

Dave lennox signature collection gas furnace upflow / horizontal air discharge
Hide thumbs Also See for SLP98UHV:
Table of Contents

Advertisement

SLP98UH090V48C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
SLP98UH090V60C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages
icomfort Touch™ Communicating Thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times
- 35%, 60%, 80%, 100% (four-stage) with time delays in-between
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28%, 38%, 70% and 100% (DIP switch selectable) of the same second-stage COOL speed position
minimum 380 cfm.
Lennox Harmony III™ Zoning System Applications - Minimum blower speed is 380 cfm.
BLOWER DATA
35%
40%
769
835
713
776
656
716
595
652
534
589
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
840
1005
1155
780
915
1045
690
835
955
35%
40%
583
665
540
618
497
571
439
507
380
443
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
1050
1270
1445
975
1120
1295
865
1010
1120
Page 43
Heating Input Range and Blower Volume - CFM
50%
60%
968
1101
902
1028
836
955
767
882
699
809
Blower Speed Selections
Second Stage Cool Speed - cfm
High
Low
(Default)
1315
1165
1190
1075
1070
935
Heating Input Range and Blower Volume - CFM
50%
60%
830
995
774
930
718
865
644
781
570
697
Blower Speed Selections
Second Stage Cool Speed - cfm
High
Low
(Default)
1620
1590
1460
1460
1290
1320
70%
80%
90%
1234
1367
1500
1155
1281
1407
1075
1195
1314
997
1112
1227
919
1029
1139
Medium-
Medium
Low
High
1375
1580
1265
1440
1145
1320
70%
80%
90%
1159
1324
1488
1085
1241
1397
1012
1159
1306
917
1054
1191
823
950
1076
Medium-
Medium
Low
High
1815
2010
1645
1845
1500
1645
100%
1633
1534
1434
1342
1249
High
(Default)
1770
1645
1465
100%
1653
1553
1453
1328
1203
High
(Default)
2195
2010
1860

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents