Figure A-2 BB-IDs left as 00 without being set
1.
Connect the system management terminal to the chassis serial port.
2.
Log in to the XSCF by using the default user account and authentication
method.
For details, see
3.
Execute the restoredefaults -c factory command to return the entire system to
the factory default settings.
XSCF> restoredefaults -c factory
WARNING:
If this system does not have BACK UP, this command will set all the user
settable XSCF configuration parameters to their default value as they
were set when the system was shipped out.
Furthermore, this command will delete all logs in the intended chassis XSCF.
Check the man page of this command before you run it.
Continue?[yes/no](default no): yes
You must check the following points.
1. Have the ability to power cycle the system.
2. Have access to the serial console and hold the serial console of the
XSCF to confirm the completion of the command.
If you answer "yes" this command will HALT the XSCF when it completes.
You will need to power cycle the system after the XSCF BOOT STOP.
Do you really want to continue?
NG
BB#00
NG
BB#00
NG
BB#00
BB#00
"6.3 Logging In to the
XSCF."
Appendix A Troubleshooting
317