Advertisement

4. A minimum of 120 square inches (774.2 square cm)
of opening, equally divided at the top and bottom of
the door, is required. Air openings are required to
be unobstructed when a door is installed. A louvered
door with equivalent air openings for the full length of
the door is acceptable.
MINIMUM INSTALLATION CLEARANCES (Inches)
SIDES
REAR
Alcove 0 (0 cm) 0 (0 cm) 15 (38.1 cm)
Closet 0 (0 cm) 0 (0 cm) 15 (38.1 cm) 1 (2.54 cm)
Closet door ventilation required: 2 louvered openings each
60 square inches (387 square centimeters) — 3 inches
(7.6 cm) from bottom and top of door.
NOTE: Under counter and stack models - 0 inches
(0 cm) for sides, rear, and top.

THIS DRYER MUST BE EXHAUSTED OUTDOORS.

5. The following illustrations show minimum clearance
dimensions for proper operation in a recess or closet
installation.
0" (0 cm)
TOP
FRONT
0" (0 cm)
CLOSET DOOR
1" (2.54 cm)
32
60 SQ. IN.
(387.1 SQ.
60 SQ. IN.
(387.1 SQ. CM)
0" (0 cm)