13 Configure the alarm settings [Alarm]
•
Default: Off
[Terminal alarm 3]
Select an action to be taken when a terminal alarm 3 is detected from the following.
•
Off: Does not take any action even when a terminal alarm 3 is detected.
•
1-64
SW395
to the selected preset position when a terminal alarm 3 is detected.
•
Auto track
SW395
•
1-256
SW396
detected, the camera will move to that position.
•
Auto track
SW396
•
Patrol 3
SW396
* If Patrol 3 is not registered it is not displayed on the screen.
•
Default: Off
[VMD alarm]
Select an action to be taken when a VMD alarm is detected from the following.
•
Off: Does not take any action even when a VMD alarm is detected.
•
1-64
SW395
to the selected preset position when a VMD alarm is detected.
•
Auto track
SW395
•
1-256
SW396
detected, the camera will move to that position.
•
Auto track
SW396
•
Patrol 1
SW396
* If Patrol 1 is not registered it is not displayed on the screen.
•
Default: Off
[Command alarm]
Select an action to be taken when a command alarm is detected from the following.
•
Off: Does not take any action even when a command alarm is detected.
•
1-64
SW395
to the selected preset position when a command alarm is detected.
•
Auto track
SW395
•
1-256
SW396
detected, the camera will move to that position.
•
Auto track
SW396
•
Patrol 1
SW396
* If Patrol 1 is not registered it is not displayed on the screen.
•
Preset per sender
the preset position for that address, the camera will move to the preset position when an alarm is detected
from the command alarm.
Click "Preset per sender >>" to open a separate window for setting preset positions for alarms.
(®page 132)
•
Default: Off
13.2.1 Configure the settings relating to Preset per sender ("Preset
per sender" setup menu) (WV-SW396/WV-SC386)
On the [Alarm] tab (®page 130), click "Preset per sender >>" for "Command alarm".
132
Operating Instructions
: When the registered preset position is selected, the camera will move
SC385
SC384
: When a terminal alarm 3 is detected, the camera will start the auto tracking.
SC385
: If a previously registered preset position is selected, when a terminal alarm 3 is
SC386
: When a terminal alarm 3 is detected, the camera will start the auto tracking.
SC386
: When a terminal alarm 3 is detected, the camera will start the patrol.
SC386
: When the registered preset position is selected, the camera will move
SC385
SC384
: When a VMD alarm is detected, the camera will start the auto tracking.
SC385
: If a previously registered preset position is selected, when a terminal alarm 1 is
SC386
: When a VMD alarm is detected, the camera will start the auto tracking.
SC386
: When a VMD alarm is detected, the camera will start the patrol.
SC386
: When the registered preset position is selected, the camera will move
SC385
SC384
: When a command alarm is detected, the camera will start the auto tracking.
SC385
: If a previously registered preset position is selected, when a terminal alarm 1 is
SC386
: When a command alarm is detected, the camera will start the auto tracking.
SC386
: When a command alarm is detected, the camera will start the patrol.
SC386
: By registering the sender's address for the command alarm and
SW396
SC386