6.3 MODBUS MEMORY MAP
Table 6–1: 489 MEMORY MAP (SHEET 21 OF 24)
ADDR NAME
2B37
VOLTS/HERTZ MAX
2B38
FREQUENCY MIN
2B39
FREQUENCY MAX
2B3C
POWER FACTOR MIN
2B3D
POWER FACTOR MAX
2B3E
REACTIVE POWER MIN
2B3F
REACTIVE POWER MAX
2B40
REAL POWER (MW) MIN
2B41
REAL POWER (MW) MAX
2B42
APPARENT POWER MIN
2B43
APPARENT POWER MAX
2B44
ANALOG INPUT 1 MIN
2B46
ANALOG INPUT 1 MAX
2B48
ANALOG INPUT 2 MIN
2B4A
ANALOG INPUT 2 MAX
2B4C
ANALOG INPUT 3 MIN
2B4E
ANALOG INPUT 3 MAX
2B50
ANALOG INPUT 4 MIN
2B52
ANALOG INPUT 4 MAX
2B54
TACHOMETER MIN
2B55
TACHOMETER MAX
2B56
THERM. CAPACITY USED MIN
2B57
THERM. CAPACITY USED MAX
2B58
NEUTRAL VOLT THIRD MIN
2B5A
NEUTRAL VOLT THIRD MAX
2B5C
CURRENT DEMAND MIN
2B5D
CURRENT DEMAND MAX
2B5E
Mar DEMAND MIN
2B5F
Mar DEMAND MAX
2B60
MW DEMAND MIN
2B61
MW DEMAND MAX
2B62
MVA DEMAND MIN
2B63
MVA DEMAND MAX
ANALOG I/O / ANALOG INPUT 1
2C00
ANALOG INPUT1
6
2C05
ANALOG INPUT1 UNITS
2C08
ANALOG INPUT1 MINIMUM
2C0A
ANALOG INPUT1 MAXIMUM
2C0C
BLOCK ANALOG INPUT1 FROM ONLINE
2C0D
ANALOG INPUT1 ALARM
2C0E
ASSIGN ALARM RELAYS (2-5)
2C0F
ANALOG INPUT1 ALARM LEVEL
2C11
ANALOG INPUT1 ALARM PICKUP
2C12
ANALOG INPUT1 ALARM DELAY
2C13
ANALOG INPUT1 ALARM EVENTS
2C14
ANALOG INPUT1 TRIP
2C15
ASSIGN TRIP RELAYS (1-4)
2C16
ANALOG INPUT1 TRIP LEVEL
2C18
ANALOG INPUT1 TRIP PICKUP
2C19
ANALOG INPUT1 TRIP DELAY
2C1A
ANALOG INPUT1 NAME
ANALOG I/O / ANALOG INPUT 2
2C40
ANALOG INPUT2
2C45
ANALOG INPUT2 UNITS
2C48
ANALOG INPUT2 MINIMUM
2C4A
ANALOG INPUT2 MAXIMUM
2C4C
BLOCK ANALOG INPUT2 FROM ONLINE
2C4D
ANALOG INPUT2 ALARM
2C4E
ASSIGN ALARM RELAYS (2-5)
2C4F
ANALOG INPUT2 ALARM LEVEL
2C51
ANALOG INPUT2 ALARM PICKUP
2C52
ANALOG INPUT2 ALARM DELAY
2C53
ANALOG INPUT2 ALARM EVENTS
2C54
ANALOG INPUT2 TRIP
2C55
ASSIGN TRIP RELAYS (1-4)
2C56
ANALOG INPUT2 TRIP LEVEL
1, 2, 3
See Table footnotes on page 6–33
6-30
RANGE
0 to 200
0 to 9000
0 to 9000
–99 to 100
–99 to 100
–200 to 200
–200 to 200
–200 to 200
–200 to 200
0 to 200
0 to 200
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
0 to 7200
0 to 7200
0 to 100
0 to 100
0 to 250000
0 to 250000
0 to 2000
0 to 2000
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 3
0 to 6
–50000 to 50000
–50000 to 50000
0 to 5000
0 to 2
1 to 4
–50000 to 50000
0 to 1
1 to 3000
0 to 1
0 to 2
0 to 3
–50000 to 50000
0 to 1
1 to 3000
0 to 12
0 to 3
0 to 6
–50000 to 50000
–50000 to 50000
0 to 5000
0 to 2
1 to 4
–50000 to 50000
0 to 1
1 to 3000
0 to 1
0 to 2
0 to 3
–50000 to 50000
489 Generator Management Relay
6 COMMUNICATIONS
STEP
UNITS
FORMAT
1
× Rated
F3
1
Hz
F3
1
Hz
F3
1
F6
1
F6
1
× Rated
F6
× Rated
1
F6
× Rated
1
F6
1
× Rated
F6
× Rated
1
F3
1
× Rated
F3
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
RPM
F1
1
RPM
F1
1
%
F1
1
%
F1
1
Volts
F10
1
Volts
F10
1
× FLA
F3
× FLA
1
F3
1
× Rated
F3
× Rated
1
F3
× Rated
1
F3
1
× Rated
F3
× Rated
1
F3
× Rated
1
F3
1
F129
1
F22
1
Units
F12
1
Units
F12
1
s
F1
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F105
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F22
1
F129
1
F22
1
Units
F12
1
Units
F12
1
s
F1
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F105
1
F115
1
F50
1
Units
F12
DEFAULT
150
5900
6100
80
–80
0
125
0
125
0
125
0
50000
0
50000
0
50000
0
50000
3500
3700
0
100
0
450
0
125
0
125
0
125
0
125
0
_
0
100
0
0
16
10
0
1
0
0
1
20
0
1
_
0
_
0
100
0
0
16
10
0
1
0
0
1
20