2.1 Components
•
iSCSI type
Figure 2.6
Figure 2.6
28
shows the closeup of the controller of the iSCSI type.
SAS (OUT) port
Connector for a miniSAS cable
Used to connect the controller enclosure to a drive enclosure.
PWC port
Used for power control.
iSCSI ports 1 (left), 0 (right)
RJ45 connectors for LAN cables
(twisted pair cable compatible with Enhanced Category 5).
LINK LED
Glows green when link has been established.
FAULT LED
Glows orange during the post power on initialization phase.
Also glows orange to indicate a fault has been detected
in the iSCSI port.
SAS (DE) LINKUP LED
Glows green when link has been established.
iSCSI type controller (rear view closeup)
Copyright 2009 FUJITSU LIMITED
LAN port (10BASE-T/100BASE-TX)
(RMT port (left), MNT port (right))
RJ45 connectors for Cat-5 twisted pair LAN cables
Each controller has two such ports.
ACT LED
Glows green when data is being sent and
received.
LINK LED
Glows green when link has been established.
MASTER LED
Glows green when LAN port is available.
UNIT READY/FAULT LED
Glows green during normal operation.
Glows orange during the post power on initialization phase.
Also glows orange to indicate a fault has been detected.
ETERNUS2000 disk storage system User Guide
P3AM-2512-03EN