2
Connect the AC outlet box outlets and power unit inlets with power cord (AC out-
put cables) (3m).
The procedures to connect the power unit is the same as the
Box" (page
The following table and figure show the connection path of an AC outlet cable and connection fig-
ure respectively
Table 4.2
Connection source
(AC outlet box outlet)
AC outlet box A
AC outlet box B
AC outlet box C
AC outlet box D
P3AM-2512-03EN
ETERNUS2000 disk storage system User Guide
77).
Connection path of a power cord (AC output cable)
(AC outlet box (4U))
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT1
OUT2
OUT3
OUT4
OUT1
OUT2
OUT3
OUT4
Copyright 2009 FUJITSU LIMITED
Step 1
in
Connection distribution
(power unit inlet)
Controller enclosure PSU#0 inlet
Drive enclosure 1 PSU#0 inlet
Drive enclosure 2 PSU#0 inlet
Drive enclosure 3 PSU#0 inlet
Drive enclosure 4 PSU#0 inlet
Drive enclosure 5 PSU#0 inlet
Controller enclosure PSU#1 inlet
Drive enclosure 1 PSU#1 inlet
Drive enclosure 2 PSU#1 inlet
Drive enclosure 3 PSU#1 inlet
Drive enclosure 4 PSU#1 inlet
Drive enclosure 5 PSU#1 inlet
Drive enclosure 6 PSU#0 inlet
Drive enclosure 7 PSU#0 inlet
Drive enclosure 8 PSU#0 inlet
Drive enclosure 9 PSU#0 inlet
Drive enclosure 6 PSU#1 inlet
Drive enclosure 7 PSU#1 inlet
Drive enclosure 8 PSU#1 inlet
Drive enclosure 9 PSU#1 inlet
Chapter 4 Setup
"4.2.6.1 With No AC Outlet
4
83