AUTODOME 7100i
Alarm stream
Select the stream to be used for alarm recordings:
Check the encoding interval and bit rates from profile: box and select an encoder profile to
set the associated encoding interval for alarm recording.
Alarm triggers
Select the alarm type that is to trigger a recording:
Export to account
Select an account from the drop-down box to export to an account. If an account has not yet
been defined, click Configure accounts to jump to the Accounts page where the server
information can be entered.
Export to account
Select this parameter if you want all alarm recordings to be exported to an FTP server
automatically. Make sure to have inserted all relevant data for FTP posting.
You can copy the settings from one profile to another with the Copy Settings button. Select
the target profile and click OK.
4.5.3

Maximum Retention Time

Maximum retention time
Enter the required retention time in hours or days for each recording. Recording 1
corresponds to Stream 1, Recording 2 corresponds to Stream 2.
Recordings are overwritten when the retention time entered here has expired.
4
Once the storage unit is full, the previous recording will be overwritten.
4.5.4

Recording Scheduler

The recording scheduler allows you to link the created recording profiles to the days and
times at which the camera's images are to be recorded. Schedules can be defined for
weekdays and for holidays.
Weekdays
Define the settings for the normal weekly schedule.
Days that have already been defined are shown in the table.
Holidays
You can define holidays that are not in the standard weekly schedule on which recordings are
to apply. This allows you to apply a schedule for Sundays to other days with dates that fall on
varying weekdays.
1.
2.
3.
Bosch Security Systems B.V.
Stream 1
Stream 2
I-frames only
Alarm input
Analysis alarm
Virtual alarm: select one of the sensors that are to trigger a recording, via RCP+
commands or alarm scripts, for example.
Enter the required retention time in days for each recording track.
Click the Holidays tab. Any days that have already been selected will be shown in the
table.
Click the Add button. A new window will open.
Select the desired date from the calendar. You can select several consecutive calendar
days by holding down the mouse button. These will later be displayed as a single entry in
the table.