62/80
CytroPac | Maintenance and repair
Measures:
Bosch Rexroth AG, Edition 07.2022, RE 51055-B
10�5�5 Visual inspection of the filling and breathing filter
▶ Carry out an annual visual inspection and replace the filling and breathing filter
as necessary, see Fig. 1, item 3.
▶ If the air filter is used as described in chapter 8.1.2 "Filling the hydraulic
power unit", annually carry out a visual inspection and replace the air filter in
case of contamination and/or damage.
10�5�6 Checking the pressure value
The pressure values need to be checked in case of any changes in drive behavior
(e.g. increased cycle time, end product quality, etc.). Otherwise, semi-annual
inspections are recommended.
Bosch Rexroth recommends documentation of pressure values in the
maintenance documentation.
10�5�7 Hydraulic fluid care
The hydraulic fluid should be analyzed at least annually.
For analyzing the hydraulic fluid, a thorough hydraulic fluid sample must be taken.
The hydraulic fluid sample must be checked in a qualified laboratory according to
the applicable manufacturer's specifications for the hydraulic fluid.
Depending on the result, additional measures need to be taken, e.g.:
• Additional filtering measures
• Dehydration
• Replacement
The use of treated and recycled hydraulic fluid (secondary raffinate hydraulic
fluid) is to be avoided.