7�3 Connecting the hydraulic supply
Pressurized system!
Danger to life, risk of injury, damage to property!
▶ Before assembling the hydraulic power unit, depressurize all relevant system
components.
Exceeded nominal pressure of a component!
Danger to life, risk of injury, damage to property!
▶ Ensure that the respective maximum operating pressure is not exceeded.
▶ Dimension the hose lines according to the maximum operating pressure.
▶ Only use components, e.g. fittings, that are approved for the required
operating pressure.
▶ Make sure that only fittings with threads measured in inches are used.
Damage to the hydraulic power unit!
Damage to property!
▶ Make sure that the connection between the hydraulic power unit and the
machine is only realized via hose lines. Do not use any rigid pipelines.
▶ Assemble the hose lines without any tension stress.
▶ Remove the blanking plugs (plastic) and replace them with pressure-resistant
Preparation
fittings.
▶ Observe the installation information of the fitting manufacturers to prevent any
external leakage.
Bosch Rexroth recommends fittings with elastic seals.
Hose lines
▶ Install the hose lines in such a way that
– buckling and tensile load at the hose is prevented during operation.
– the hose is not twisted.
– the outer layer of the hose is not subject to abrasion or impacts.
– the weight of the hose line does not lead to inadmissible loads.
If failure of a hose line may cause hazards caused by whipping, Bosch Rexroth
recommends mounting a hose safety catch. If the hose lines are equipped with
tear-proof fittings, a hose safety catch is not required.