6.2.2

Output Parameters

P2
P3
High Byte
Code
[hex]
00
Job is finished (terminated) without error
01
Job on the RSS is being processed
02
Job is in the queue of the RSS
03
Job is finished with error
04
No job with this job number is being processed
1070 072 196-101 (00.06) GB
Parameter
P2
Into this parameter, R5CON writes the number of that job whose status and
error codes are available in the P3 and P4 output parameters.
If an explicit job number has been specified in P1, it will be mirrored in P2.
If after the parameterization with P1 = 16#FFFF no job is finished, the value
16#FFFF will be returned to P2 as a job number.
If after the parameterization of P1 = 16#FFFE no faulty job, but one or more
jobs without error message are finished, the value 16#FFFE will be returned
to P2.
Parameter
P3
In this word, the current job status is output with each execution of R5CON.
The current job status is indicated in the high byte of this word.
The low byte of P3 provides a code that recommends to the user a suitable
measure in case of an error (PLC reaction). This code becomes valid after
the job has been finished.
Job Status
Attribute
Description
W
Job number
Attribute
Description
W
Status / PLC reaction
Code
[hex]
00
Error-free operation
01
Repeat call of the R5CON function module
02
Change PLC program
03
Check and change job parameter
04
Execute R5INIT function module again
05
Execute R5REQ function module again
06
Execute R5CON function module again
50
Undefined error code, no reaction possible
R5CON
Low Byte
PLC Reaction
6- -3