Power Supply Equipment - Panasonic YD-500GP5 Operating Instructions Manual

Digital igbt control mig/mag power source
Table of Contents

Advertisement

3.3 Power supply equipment

welding power source
Input power source
Capacity
Input protection
(Power distribution box)
Cross-section area
Of cable
Protection level
Insulation level
class of pollution
EMC classification
*1. The listed capacities of fuses and breakers (or leakage protectors) are only for reference.
*2. When the machine is working at the places where are moist or on the iron plate or stand, please be sure to
install leakage protector.
Note:
please follow the regulations listed below to avoid any damage of parts, unstable arc and overheat or damage of
the machine.
● The fluctuation range of input: the allowable rated input voltage is 304V ~ 456V.
● When the generator is used, the rated input capacity should be two times of welding power source or higher.
The generator should be equipped with compensating coils.
● The wiring of input side: please equip each welding power source with one fuse switch or non-fuse breaker (or
leakage breaker) of which capacity complies with the rated one of the cutting power source.
● Please select the proper breaker (or leakage breaker) which is applicable to electric distribution, such as cutting,
electric motor or transformer.
Installation and Power supply facility
Observe the following to prevent burnout, destruction of parts and unstable
arc.
Commercial power source
Engine generator
Fuse breaker
Molded case circuit breaker
(or leakage breaker)
Input power cable
Output power cable
Ground cable
YD-500GP5
Three phase ,400V AC,
50 / 60 Hz (common)
35 kVA or more
Two times rated input or more
10 mm
70 mm
The same as input power cable or bigger
main transformer 155 ℃( inductor 200 ℃)
10
63 A
80 A
2
or more
2
or more
IP23S
Class 3
Class A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents