Spot Welding Operation; Stick Welding Operation - Panasonic YC-300BZ3YHD Operating Instructions Manual

Dc tig welding power source
Table of Contents

Advertisement

Operation

9.2 SPOT welding operation

There is no pulse function in the case of the Spot weld-
ing.
Even with the torch switch turned on, welding terminates
when the arc spot time has elapsed.
Torch switch
Output current
Shield gas

9.3 STICK welding operation

To prevent an electric shock, touching any live parts of the electrode holder may cause a fatal
electric shock and/or burns.
• Unless there is any particular inconvenience, use the product with the electric shock preventing
"ON" side. (Factory setting: ON)
• When no welding operation is required, keep the power switch turned off. (Or, set the welding method switch to
any mode other than "STICK".)
Bring the tip of a coated electrode into contact with the
base material to have an arc generated.
(To stop the arcing, withdraw the tip of a coated electrode
from the base material.)
Note
With regard to the DC stick welding, it may be difficult to
perform the welding depending on the type of electrodes
42
Arc spot time
Pre-flow
CAUTION
(*
See section "Names and functions: Function setting devices" for details.)
Note
When the torch switch is turned off during the arc spot
time, the welding operation is terminated immediately.
ON
(No self-hold)
Post-flow
(ex. low-hydrogen type electrode, etc.) and/or welding
methods. Therefore, it is recommended to perform a weld-
ing test in advance.
OFF
function*
set to the
OMCTT5621E18