RX Band Filter Response Compensation
•
RF generator needed
•
RX Band Filter Response Compensation starts at EGSM (GSM900),
then continues at GSM1800 band.
•
NOTE! Remember to do RX calibration before doing Rx Band Filter
Response Compensation!
•
Remember to take jig and cable attenuations into account!
Select Tuning => GSM => Rx Band Filter Response Compensation
Select "Manual tuning" and "Start"
You will be asked to supply 9 different RF frequencies to the phone
Set first required frequency and level => OK