Ademco High Speed 4-8-1, Scancom 4-8-1 (Message Type F) - Bosch Conettix D6600 Manual

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.6

Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f)

SCANCOM 5-8-1, 6-8-1 - available upon request
High Speed
SIA Mode Description
Example
<LF><CRC><f><sequence#><receiver#><line#>[#aaaaaa|CCCCsCCCCsC]<CR>
Table 51: Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type F) Byte Description
Title
LF
CRC
Message Type
sequence#
receiver#
line#
(Line/Group #)
account#
CCCC
s
CCCC
s
C
Figure 12: Message sent to printer
mm/ddshh:mmsLxxsHGHsACCTsaaaaaa
+++sACCTsaaaaaasCCCCsCCCCsC
For lines that are grouped, Gxx appears instead of Lxx.
Table 52: Ademco High Speed, 4-8-1 (Message Type f) Printer Output
Characters
Description
HGH
Ademco High Speed format.
Lxx:
Line number.
Gxx
Grouped line numbers.
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Description
Standard line feed character.
Cyclical redundancy check number.
f
The message sequence number. The valid sequence number range is
0001 to 9999.
The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.
The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.
The communicator's account number has up to six digits.
Channels 1 to 4.
One space.
Channels 5 to 8.
One space.
Supervisory channel.
49