Combined Keyboard/Mouse Interface; Mouse Interface; Fig. 7-8: Combined Keyboard/Mouse Interface Xkeyb; Fig. 7-9: Mouse Interface Xmouse - Bosch Rexroth IPC 40.2 Project Planning Manual

Table of Contents

Advertisement

7-8
Connections

Combined Keyboard/Mouse Interface

XKeyb. – PS/2 Mini DIN
Keyboard / Mouse Interface

Mouse Interface

XMouse – PS/2 Mouse Interface
PS/2 Mini-DIN female connector, 6-pin
Cable length:
Cable type:
X
Keyb
5
6
4
3
2
1
Shield
Fig. 7-8:
Combined keyboard/mouse interface XKeyb.
Note:
If a BTT or VDP is connected, keyboard and mouse may only
be connected to the display and never to the IPC 40.2.
PS/2 Mini-DIN female connector, 6-pin
Cable length:
Cable type:
Interrupt (IRQ):
BIOS presettings:
XMouse
Shield
Fig. 7-9:
Mouse interface XMouse
If a PS/2 mouse is not recognized by the system, the mouse has to be
activated in the BIOS by switching from "Disabled" to "Autodetect". The
operating system will not recognize the plugging-in of an external mouse
after completed startup, because the mouse initialization occurs during
the booting process.
Max. 1.5 m
Shielded, cross section min. 0.14 mm²
max. 1.5 m
1
Keyboard Data
2
Keyboard
Mouse Data
3
GND
4
Power, +5VDC
5
Keyboard Clock
6
Mouse Clock
Shield applied to the
metal housing of the
plug-in connector
Max. 1.5 m
Shielded, cross section min. 0.14 mm²
12
PS/2 mouse support: Enabled
PS/2 mouse: Auto detect
1
Mouse Data
2
Mouse
3
GND
4
Power, +5 VDC
5
Mouse Clock
6
Shield applied to the metal housing
of the plug-in connector
DOK-SUPPL*-IPC*40.2***-PR02-EN-P
IPC 40.2
tastatur_sst.cdr
max. 1.5 m
maus_sst.cdr