In the upper right part of the connector panel there are five LEDs to
indicate the device states and errors. Start the measure specified in the
following table, if one of the succeeding LEDs indicates an error or a note.
LED
Indicator
Meaning
Vi
LED
Normal mode
green
LED OFF
No supply voltage
230/115 VAC or 24 VDC
Vo
LED
Normal mode
green
LED OFF
Internal 5 V supply faulty!
T
LED OFF
Normal mode
LED
Over-temperature
yellow
flashing
UPS
LED OFF
Normal mode
LED red
Industrial PC is currently
operating in battery mode,
i. e. no power supply
available!
LED red
Battery pack discharged,
flashing
defective or not connected
HDD
LED
Hard disk access
yellow
Fig. 6-1:
LEDs to indicate operations and errors on the connector panel
IPC 40.2
Measure
-
Check supply voltage at
the power supply unit!
-
-
Reduce ambient
temperature
(surrounding air
temperature)!
Check fan at the PC!
-
Restore power supply
and initiate controlled
BTV restart!
Check battery pack!
Maintain the charging
time of 5 hours!
-