Settings; Function Settings; F. Adj - Panasonic YD-350GL4 Operating Instructions Manual

Digital igbt controlled mig / mag arc welding power source
Table of Contents

Advertisement

8. Settings
8.1 FUNCTION settings
8.1.1 "F. ADJ"
The following table shows the pages and parameters for
fine adjustment/settings using the "F. ADJ".
(1)Use the Mode selection key ○
It shows P00 in ○
2
(2)In ○ 4 , select the item (P00~P29) to be changed.
It shows item in ○
2
Note please don't turn ○
(The set value in ○
5
(3)When you want to change the set value of the selected
item, turn ○
, The set value is shown in ○
7
(4)After operation, select the other mode than "F. Adj"
According to (3) operation, you can decide the set value
Note the circled digits are in correspondence with that of
the parts on the right drawing. On F. Adj status, welding is
not enabled but gas check function works.
【Basic Control】
NO.
Menu contents
P00
SLOW DOWN
PRE FLOW
P04
TIME
AFTER FLOW
P05
TIME
UNITARY·
P10
respectively
External remote
P11
control
Loop resistance
P12
Compute
to select F. Adj. (During welding, it can NOT be selected.)
12
and 00 in ○
.
5
and set value in ○
.
5
Jog-dial arbitrarily.
7
can change.)
.
5
Set range
Increment
1
-5 ~5
0.1
-5 s ~ 5 s
0.1s
-5s~5 s
0.1s
0 or 1
0 or 1
0 or 1
2

Settings

1
2
3
8
4
Default
Fine adjustment of slowdown speed.
0.1
Increase the set value to increase the
slow-down speed.
It specifies time to feed wire after starting gas
0.1s
supply by turning on the torch switch.
It specifies time to stop gas supply after
0.1s
stop-ping the arc by turning off the torch
switch.
1: Welding voltage unification;
1
1
0: The welding voltage is respectively.
1: The power supply preset current and preset
voltage are adjusted by the operation panel
encoder;
1
0
0: The power supply preset current and preset
voltage are adjusted by the wire feeder remote
control.
When set to 1, the mode selection key
selected for soldering. Make sure the contact
tip is in close contact with the base material.
1
0
Press the torch switch. The digital tube ○ 5
shows the corresponding resistance value (unit:
0.0001Ω).
21
5
6
12
13
10
9
11
7
15
16
Note
18
14
19
17
○ 12 is

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yd-500gl4

Table of Contents