Manuals and User Guides for YL Instruments YL9100 HPLC. We have
1
YL Instruments YL9100 HPLC manual available for free PDF download: User Manual
YL Instruments YL9100 HPLC User Manual (188 pages)
High Performance Liquid Chromatograph
Brand:
YL Instruments
| Category:
Laboratory Equipment
| Size: 4.97 MB
Table of Contents
Yl9101 Vacuum Degasser
3
Table of Contents
3
Chapter 1. Introduction
4
Specifications
4
Chapter 2. Installation
5
Inspection and Site Preparation
5
Connection of Power
5
Connection of Tubing
6
Connecting of Mobile Phase Solvent
6
Connecting of Solvent Delivery Pump
6
Chapter 3. Operation
7
Degassing of the Solvent
7
Operating of Solvent Delivery Pump
7
Replacing Solvents
7
Keeping Method after Use
7
Chapter 4. Maintenance
8
Filtration of Solvent
8
Caution
8
Troubleshooting
8
Yl9110 Quaternary Solvent Delivery Pump
10
Chapter 1. Introduction
13
Specifications
14
Chapter 2. Configuration and Principle
15
Configuration of Flow Path
15
Compressibility Compensation
17
Operation
17
Solenoid Valve Control
18
Gradient Curve
19
Rinse Port
19
Chapter 3. Installation
20
Inspection and Site Preparation
20
Connection of Power
21
Connection of Tubing
21
Fig. 5] Fitting for 1/16" OD Tubing
22
Fig. 6] Connection between YL9110 Quaternary Pump and YL9100 HPLC System
23
Connection of Remote Cable
24
Fig. 10] Diagram of Remote and Marker Input
25
Connection of Communication Cable
26
Before Start
27
Chapter 4. Operation
27
Mobile Phase Filter and Bottle
28
Preparation of Solvent
28
4-3-1.Degassing
28
Filtration
29
Solvent Effect on the Instrument
29
Measures When Not Uses for Long Time
30
YL-Clarity Chromatograph Software
30
4-4-1.Installation of Pump
30
Device Monitor
32
Method Setup
33
Error Message
34
Chapter 5. Maintenance
35
Caution
35
Replacement of High Pressure Seal
35
Fig. 14] Replacement of High Pressure Seal
36
Replacement of Plunger
37
Replacement of Check Valve Cartridge
38
Replacement of Low Pressure Seal
38
Cleaning of Flow Path Within Pump
38
Supply of Lubricant
39
Replacement of Solvent Filter and In-Line Filter
39
After Use System
41
Troubleshooting
42
Yl9111 Binary Pump
45
Chapter 1. Introduction
48
Specifications
49
Chapter 2. Configuration and Principle
50
Configuration of Flow Path
50
Compressibility Compensation
52
Operation
52
Gradient Curve
53
Rinse Port
54
Chapter 3. Installation
55
Inspection and Site Preparation
55
Connection of Power
56
Connection of Tubing
56
Connection of Remote Cable
59
Connection of Communication Cable
61
Before Start
62
Chapter 4. Operation
62
Mobile Phase Filter and Bottle
63
Preparation of Solvent
63
4-3-1.Degassing
63
Filtration
64
Solvent Effect on the Instrument
64
Measures When Not Uses for Long Time
65
YL-Clarity Chromatograph Software
65
4-4-1.Installation of Pump
65
Device Monitor
67
Method Setup
68
Caution
70
Chapter 5. Maintenance
70
Replacement of High Pressure Seal
70
Replacement of Plunger
72
Cleaning of Flow Path Within Pump
73
Replacement of Check Valve Cartridge
73
Replacement of Low Pressure Seal
73
Replacement of Solvent Filter and In-Line Filter
74
Supply of Lubricant
74
After Use System
76
Yl9112 Isocratic Pump
80
Chapter 1. Introduction
83
Specifications
84
Chapter 2. Configuration and Principle
85
Configuration of Flow Path
85
Compressibility Compensation
87
Operation
87
Rinse Port
88
Chapter 3. Installation
89
Inspection and Site Preparation
89
Connection of Power
90
Connection of Tubing
90
Connection of Remote Cable
93
Connection of Communication Cable
95
Before Start
97
Chapter 4. Operation
97
Mobile Phase Filter and Bottle
98
Preparation of Solvent
98
4-3-1.Degassing
98
Filtration
99
Solvent Effect on the Instrument
99
Measures When Not Uses for Long Time
100
YL-Clarity Chromatograph Software
100
4-4-1.Installation of Pump
100
Device Monitor
102
Method Setup
103
Error Message
104
Caution
105
Chapter 5. Maintenance
105
Replacement of High Pressure Seal
105
Replacement of Plunger
107
Cleaning of Flow Path Within Pump
108
Replacement of Check Valve Cartridge
108
Replacement of Low Pressure Seal
108
Replacement of Solvent Filter and In-Line Filter
109
Supply of Lubricant
109
After Use System
111
Troubleshooting
111
Yl9120 Uv/Vis Detector
115
Chapter 1. Introduction
117
Features of YL9120
117
Specifications
117
Chapter 2. Installation
119
Inspection and Site Preparation
119
Connection of Power
120
Connection of a Column
120
Connection of Remote Cable
121
Connection of Communication Cable
122
Chapter 3. Operation
124
YL-Clarity Chromatograph Software
124
Installation of Uv/Vis Detector
124
Method Setup
127
Error Message
129
Chapter 4. Maintenance
130
D2 Lamp
130
How to Remove the D
130
Lamp
130
How to Install a New D
131
Lamp
131
Tungsten Lamp (W)
131
How to Remove the Tungsten Lamp
132
How to Install a New Tungsten Lamp
133
Flow Cell Cleaning
133
Troubleshooting
134
Yl9130 Column Compartment
137
Chapter 1. Introduction
138
Specifications
138
Chapter 2. Installation
139
Inspection and Site Preparation
139
Connection of Power
140
Installation of Switching Valve and Column
140
Connection of Remote Cable
142
Connection of Communication Cable
143
Chapter 3. Operation
144
Yl9160 Pda Detector
151
Chapter 1. Introduction
152
Features of YL9160
152
Specifications
152
Optics Design
153
Chapter 2. Installation
155
Inspection and Site Preparation
155
Connection of Power
156
Connection of a Column
156
Connection of Remote Cable
157
Connection of Communication Cable
159
Chapter 3. Operation
160
YL-Clarity Chromatograph Software
160
Chapter 4. Maintenance
164
D2 Lamp
164
How to Remove the D
164
Lamp
165
How to Install a New D Lamp
165
Tungsten Lamp (W)
165
How to Remove the Tungsten Lamp
166
How to Install a New Tungsten Lamp
166
Flow Cell Cleaning
167
Troubleshooting
167
Yl9170 Ri Detector
170
Tchapter 1. Introduction
171
T1-1. Features of YL9170
171
Specifications
171
Chapter 2. Installation
172
Inspection and Site Preparation
172
Connection of a Column
173
Connection of Cables
174
Chapter 3. Operation
175
YL-Clarity Chromatograph Software
175
Chapter 4. Maintenance
179
Adjusting the Optical System
180
Lamp Exchange and Adjustment of the Lamp
181
Checking Sum and Difference Voltages
184
Check and Replacement of the Valve
185
Checking and Cleaning the Flow Cell
186
The Heating Circuit of the Detector
187