Sign In
Upload
Manuals
Brands
wtw Manuals
Accessories
DIQ/S 282
wtw DIQ/S 282 Manuals
Manuals and User Guides for wtw DIQ/S 282. We have
1
wtw DIQ/S 282 manual available for free PDF download: Operating Manual
wtw DIQ/S 282 Operating Manual (186 pages)
IQ SENSOR NET SYSTEM 28X FOR 2 OR 4 DIGITAL IQ SENSORS
Brand:
wtw
| Category:
Accessories
| Size: 2.3 MB
Table of Contents
Table of Contents
3
1 Overview
9
Structure and Function
9
Functions in the IQ SENSOR NET
13
Interfaces
14
USB Interface
14
Ethernet Interface (DIQ/S 28X-E[F])
14
Fieldbus Interface (DIQ/S 28X -MOD, -PR, -EF)
15
Behaviour of the System to a Power Failure
15
2 Safety
16
Safety Information
16
Safety Information in the Operating Manual
16
Safety Signs on the Product
16
Further Documents Providing Safety Information
16
Safe Operation
17
Authorized Use
17
Requirements for Safe Operation
17
Unauthorized Use
17
User Qualification
17
3 Installation
18
Scopes of Delivery
18
Basic Principles of Installation
18
Requirements of the Measurement Location
18
Safety Requirements of the Electrical Installation
18
Installation Guidelines for Lightning Protection
19
Drawing up the Power Rating
21
Connecting the Sensor
26
On-Site Mounting of the DIQ/S 28X
28
General Information
28
Mounting on a Mounting Stand with the SSH/IQ Sun Shield
29
Mounting under the SD/K 170 Sun Shield
31
Top hat Rail Mounting
32
Panel Mounting
33
Electrical Connections: General Instructions
36
Connecting the Voltage Supply
37
DIQ/S 28X (Line Power Version)
38
DIQ/S 28X[-XX]/24V (24 V Version)
41
Connections to the Relay and Current Outputs
44
General Installation Instructions
44
Usage of the Auxiliary Voltage
46
Commissioning
47
Installation Examples
49
Connecting Two Sensors Without Compressed Air Cleaning
49
Connecting Two Sensors with Compressed Air Cleaning
50
Connection of a Sensor that Is Located at a Distance
52
(Without Compressed Air Cleaning)
52
Figures of the Terminal Strips
53
4 Operation
54
Operating Elements
54
Overview of the Operating Elements
54
Display
55
Keys
57
General Operating Principles
57
Navigating in Menus, Lists and Tables
58
Entering Texts or Numerals
59
Access to the IQ SENSOR NET with Active Access Control
61
Display of Current Measured Values
62
Displaying a Single Measured Value
63
Displaying Four Measured Values
63
Displaying Eight Measured Values
63
Displaying Recorded Measured Values
64
Transmitting Recorded Measurement Data to a PC
66
Messages and Log Book
66
Message Types
66
Log Book
67
Viewing Detailed Message Texts
70
Acknowledge All Messages
71
Calibration Data
72
Calibration Entries in the Log Book
72
Calibration History
72
Status Info of Sensors and Outputs
73
General Course When Calibrating, Cleaning, Servicing or Repairing an IQ Sensor
74
Maintenance Condition of IQ Sensors
74
Switching on the Maintenance Condition
75
Switching off the Maintenance Condition
76
USB Interface
77
Saving IQ SENSOR NET Data to a USB Memory Device
77
Restore System Configuration
78
Info on Software Versions
78
Software-Update for DIQ/S 28X
79
5 Settings/Setup
80
Selecting the Language
80
Terminal Settings of the DIQ/S 28X
80
Access Control
81
Activating the Access Control
82
Activating the Instrument Block
85
Electronic Key
85
Access to the IQ SENSOR NET with Active Access Control
86
Editing the List of Sensors
86
Entering / Editing a Name for an IQ Sensor
87
Changing the Display Position
88
Erasing Inactive Sensor Datasets
88
Settings for Sensors
89
Sensor-Sensor Link
91
(Automatic Offset of an Influencing Quantity)
91
Establishing the Sensor-Sensor Link
91
Erasing a Sensor-Sensor Link
94
Editing the List of Outputs
95
Entering / Editing the Name of an Output
95
Erasing an Inactive Dataset for an MIQ Output Module
96
Output Links/Settings
97
Alarm Settings
97
General Information
97
Setting up / Editing Alarms
98
Alarm Output to Display
100
Alarm Output as Relay Action
101
Alarm Message as Email (Variant -E, EF)
101
System Settings
102
Changing the Password
102
Setting the Date and Time
103
Location Altitude / Average Air Pressure
104
TCP/IP Settings (Variant -E, EF)
105
Email (Variant -E, EF)
106
Settings Bus Interfaces (Variant -E, EF)
108
Function Code
108
Measured Value Logging
108
Setting the Recording Interval (Dt) and Recording Duration (Dur.)
109
6 Ethernet Connection (Variant -E, -EF)
111
Configuring the Ethernet Network
111
Communication in a Local Network (LAN)
113
Communication on the Internet
114
Ethernet Connection if Mounted at an Open Air Test Site (DIQ/S 28X-E[F])
116
Establishing the Connection with the DIQ/S 28X Via a Network
116
Opening the IQ WEB CONNECT
116
IQ WEB CONNECT Terminal
117
Iq Web
117
Datalogtransfer
118
IQ WEB CONNECT Configsaveload
120
Communication with Fieldbuses (DIQ/S 28X[-XX]-EF)
120
Troubleshooting
120
Technical Network Terms
122
7 Outputs
124
Outputs of the System 28X
124
Basic Information on Relay Functions
125
Monitoring
125
Limit Indicator
125
Proportional Output
126
Entering / Editing the Name of an Output
133
Linking the Output with a Sensor
134
Deleting a Link with an Output
135
Setting the Relay Outputs
136
Relay Action
137
System Monitoring
138
Sensor Monitoring
139
Limit Indicator
140
Frequency Controller
140
Pulse-Width Output
142
Cleaning
143
Sensor-Controlled
146
Manual Control
147
Alarm Contact
147
Setting the Current Outputs (Variant -CR3, CR6)
147
Recorder
148
PID Controller
149
Fixed Current Value
154
Checking the Condition of the Outputs
155
Behavior of Linked Outputs
156
Behavior in Case of Error
156
Behavior in Non-Operative Condition
157
Maintenance Condition of the Sensors
157
Switching on the Maintenance Condition
158
Switching off the Maintenance Condition
158
8 Maintenance and Cleaning
159
Maintenance
159
Cleaning
159
9 What to Do if
160
Information on Errors
160
Errors: Causes and Elimination
160
Replacing System Components
161
Replacing Passive Components
161
Adding and Replacing IQ Sensors
161
Adding and Replacing DIQ or MIQ Output Modules
164
10 Technical Data
168
Diq/S 282, Diq/S 284
168
General Data of MIQ Modules
175
Diq/Jb
177
Diq/Chv
178
Space Required by Mounted Components
179
11 Accessories and Options
180
12 Messages
181
Explanation of the Message Codes
181
Error Messages
181
Informative Messages
182
13 Index
183
Advertisement
Advertisement
Related Products
wtw DIQ/S 284
wtw DIQ/S 182
wtw DIQ/CR3
wtw DIQ/S 181
wtw AmmoLyt 700 IQ
wtw AmmoLyt Plus 700 IQ
wtw Br 500 BNC
wtw Br 800 BNC
wtw Br 800 DIN
wtw CarboVis 70 Series
wtw Categories
Measuring Instruments
Accessories
Laboratory Equipment
Control Unit
Touch terminals
More wtw Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL