Table of Contents
Table of Contents
3
1 Introduction and Application
5
2 Features and Characteristics
6
3 Design
7
Connections
7
Analog Input Circuits
7
Blocking Input
7
External Reset Input
7
Output Relays (Default Settings)
8
Data Communication
9
Front Plate
10
Indication and Operation Elements
10
Display
11
Leds
12
Parameter Settings (See Chapter 6)
12
4 Working Principle
13
Analog Circuits
13
Digital Circuits
13
Directional Feature
14
Requirements on the Main Current Transformers
15
5 General Operations and Settings
16
Push Buttons
16
Indication of Measuring Values and Fault Data
17
Dip Switches
18
Function of the Output Relays
18
Reset
19
Password
19
Password Programming
19
Using the Password
19
Relay Setting Principle
20
Setting of Default Parameters
20
Blocking the Protection Function
20
Display of Software Version and Test-TRIP
21
Low/High Range of Functions Blocking and Reset
21
6 Operations and Settings
22
Setting Procedure
22
Pickup Current for Phase Overcurrent Element (I>)
22
Time Current Characteristics for Phase Overcurrent Element (CHAR I>)
22
Trip Delay or Time Multiplier for Phase Overcurrent Element (Ti>)
22
Reset Setting for Inverse Time Tripping Characteristics in the Phase Current Path
23
Current Setting for High Set Element (I>>)
23
Trip Delay for High Set Element (Ti>>)
23
Relay Characteristic Angle RCA
24
Nominal Frequency
24
Adjustment of the Slave Address
24
Circuit Breaker Failure Protection T
24
Display of the Activation Storage (FLSH/NOFL)
24
Cbfp
24
Blocking the Protection Functions and Assignment of the Output Relays
25
Setting Value Calculation
26
Definite Time Overcurrent Element
26
Inverse Time Overcurrent Element
27
Indication of Measuring and Fault Values
27
Measuring Values
27
Indication of Fault Data
27
Fault Recorder
28
Reset
29
7 Relay Testing and Commissioning
30
Power-On
30
Testing the Output Relays and Leds
30
Checking the Set Values
30
Secondary Injection Test
31
Test Equipment
31
Test Circuit of XRI1-IR
31
Checking the Input Circuits and Measured Values
33
Checking the Operating and Resetting Values of the Relay
33
Checking the Relay Operating Time
33
Checking the High Set Element of the Relay
33
Checking the External Blocking and Reset Functions
34
Test of the CB Failure Protection
34
Primary Injection Test
35
Maintenance
35
8 Technical Data
36
Measuring Input Circuits
36
Common Data
36
Setting Ranges and Steps
37
Time Overcurrent Protection
37
Switch Failure Protection
37
Interface Parameter
37
Inverse Time Overcurrent Protection Relay
37
Direction Unit for Phase Overcurrent Relay
38
Inverse Time Characteristics
39
Output Relays
41
Power Supply
41
Inputs, Blockage and Reset
41
System Data and Test Specifications
42
Relay Case
43
9 Order Form
44
Advertisement
Advertisement
Related Products
Woodward XRI1-ER
Woodward XR1
Woodward XRN2
Woodward XRN2-1
Woodward XRN2-2
Woodward easYprotec-1000 Series
Woodward easYprotec-1410
Woodward EM300
Woodward EM80
Woodward ESDR 4
Woodward Categories
Controller
Control Unit
Relays
Control Systems
Industrial Equipment
More Woodward Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL