User Manuals: Watts Aerco ProtoNode FPC-N35 Boiler
Manuals and User Guides for Watts Aerco ProtoNode FPC-N35 Boiler. We have
1
Watts Aerco ProtoNode FPC-N35 Boiler manual available for free PDF download: User Manual
Watts Aerco ProtoNode FPC-N35 User Manual (108 pages)
Serial, LonWorks
Brand:
Watts
| Category:
Gateway
| Size: 4.22 MB
Table of Contents
Table of Contents
3
Quick Start Guide
6
CHAPTER 1. Introduction
7
Protonode Gateway
7
CHAPTER 2. Bacnet/Lonworks Setup for Protonode FPC-N34/FPC-N35
11
Record Identification Data
11
Point Count Capacity and Registers Per Device
11
Configuring Device Communications
12
Set Modbus COM Setting on All of the Devices Connected to the Protonode
12
Set Modbus RTU Node-ID for each of the Devices Attached to the Protonode
12
Selecting the Desired Field Protocol and Enabling Auto-Discovery
12
Selecting Desired Field Protocol
12
Enabling Auto-Discovery (Not Used on BST or WHM)
13
Manually Selecting Your Equipment
14
BAS Network Settings: MAC Address, Device Instance and Baud Rate
14
Bacnet MS/TP (FPC-N34): Setting the MAC Address for BAS Network
14
Bacnet MS/TP and Bacnet/Ip (FPC-N34): Setting the Device Instance
15
Metasys N2 or Modbus TCP/IP (FPC-N34): Setting the Node-ID
16
Bacnet MS/TP or Modbus RTU (FPC-N34): Setting the Baud Rate for BAS Network
16
CHAPTER 3. Interfacing Protonode to Devices
17
Protonode FPC-N34 and FPC-N35 Showing Connection Ports
17
Device Connections to Protonode
18
Biasing the Modbus RS-485 Device Network
19
End of Line Termination Switch for the Modbus RS-485 Device Network
20
Network
21
Lonworks (FPC-N35): Wiring Field Port to Lonworks Network
21
ACS/BMS II Wiring Connections to Protonode FPC-N34 and FPC-N35
22
Modulex BCM Connections
23
ECS Connections
23
C-MORE Connections
24
AM Series Connections
24
Power-Up Protonode
25
Auto-Discovery: after Completion - Turn off to Save Configuration
26
CHAPTER 4. Bacnet/Ip or Modbus TCP/IP: Change the Protonode IP Address
27
Connect the PC to Protonode Via the Ethernet Port
27
Bacnet/Ip and Modbus TCP/IP: Setting IP Address for Field Network
29
CHAPTER 5. Bacnet MS/TP and Bacnet/Ip: Setting Node_Offset to Assign Specific Device Instances
31
CHAPTER 6. How to Start the Installation Over: Clearing Profiles
33
CHAPTER 7 . Lonworks (FPC-N35): Commissioning Protonode on a Lonworks Network
35
Commissioning Protonode FPC-N35 on a Lonworks Network
35
Instructions for Downloading XIF File from Protonode FPC-N35 Using Browser
35
CHAPTER 8. CAS Bacnet Explorer for Validating Protonode in the Field
37
Downloading the CAS Explorer and Requesting an Activation Key
37
CAS Bacnet Setup
38
CAS Bacnet MS/TP Setup
38
CAS Bacnet Bacnet/Ip Setup
39
Appendix A: "A" Bank DIP Switch Settings
41
Appendix B: AERCO Equipment Monitor and Control Point Definitions
45
Appendix B-2: AERCO Electronic Control System (ECS) Point Definitions
48
Appendix B-3: AERCO (Modulex) BCM Point Definitions
48
Appendix B-4: Water Heater Management System (WHM) and On-Board Boiler Sequencing Technology (BST) Point Definitions
50
Appendix B-5: am Series Point Definitions
53
Appendix C: AERCO Equipment Point Mappings
57
Appendix C-1: am Mngr Modbus RTU Mappings to Bacnet MS/TP, Bacnet/Ip, Metasys N2, Modbus TCP/IP and Lonworks
57
Appendix C-2: am Dep Modbus RTU Mappings to Bacnet MS/TP, Bacnet/Ip, Metasys N2, Modbus TCP/IP and Lonworks
61
Appendix C-3: C-More Modbus RTU Mappings to Bacnet MS/TP, Bacnet/Ip, Metasys N2, Modbus TCP/IP and Lonworks
63
Appendix C-4: Modulex Modbus RTU Mappings to Bacnet MS/TP, Bacnet/Ip, Metasys N2, Modbus TCP/IP and Lonworks
63
Appendix C-5: ECS Modbus RTU Mappings to Bacnet MS/TP, Bacnet/Ip, Metasys N2, Modbus TCP/IP and Lonworks
64
Appendix C-6: ACS/BMSII/BMS Modbus RTU Mappings to Bacnet MS/TP, Bacnet/Ip, Metasys N2, Modbus TCP/IP and Lonworks
65
Appendix D: Eight C-More Boilers/Heaters and BST/WHM Master
67
Appendix E: Troubleshooting
77
Appendix E-1: Viewing Diagnostic Information
77
Appendix E-2: Check Wiring and Settings
78
Appendix E-3: Diagnostic Capture with the Fieldserver Utilities
79
Appendix E-4: Bacnet: Setting Network_Number for more than One Protonode on Subnet
82
Appendix E-5: LED Diagnostics for Modbus RTU Communications between Protonode and
83
Devices
83
Appendix E-6: Passwords
84
Appendix F: C-More Status and Fault Messages
85
Appendix G: Conversion Equations for Temperature Variables
91
Appendix H: BCM and BMM Fault Codes for Modulex E8 Controller
93
Appendix H-1: BCM and BMM Fault Code Conversion Table
93
Appendix H-2: BMM Fault Code Table
94
Appendix H-3: BCM Fault Code Table
96
Appendix I: am Error, State and Status Tables
98
Appendix I-1: am Lockout Error Codes Table
98
Appendix I-2: am Blocking Error Codes Table
99
Appendix I-4: am Status Parameters Table
100
Appendix I-3: am State Parameters Table
100
Appendix I-5: Cascade Connection of am Boiler with Protonode
101
Appendix J: Reference
104
Appendix J-1: Specifications
104
Appendix J-2: Compliance with UL Regulations
104
Appendix K: Limited 2 Year Warranty
107
Advertisement
Advertisement
Related Products
Watts Aerco ProtoNode FPC-N34
Watts FP-BF-CFS-1/2-2
Watts FP-BF-BMS-1/2-2
Watts FP-RFK-BF-BMS-CFS-2
Watts FP-RFK-BF-CFS-1-11/2
Watts FP-RFK-BF-BMS-CFS-1-11/2
Watts FP-RFK-BF-CFS-2
Watts FG1B Series
Watts FGD20