Sign In
Upload
Manuals
Brands
VorTek Manuals
Measuring Instruments
Pro-T
VorTek Pro-T Manuals
Manuals and User Guides for VorTek Pro-T. We have
1
VorTek Pro-T manual available for free PDF download: Instruction Manual
VorTek Pro-T Instruction Manual (150 pages)
Vortex Volumetric and Mass Flow Meters
Brand:
VorTek
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
4
Chapter 1 Introduction
11
Using this Manual
11
Note and Safety Information
12
Receipt of System Components
12
Technical Assistance
12
Velocity Measurement
13
In-Line Vortex Multi-Parameter Mass Flow Meter
13
Vortex Shedding Frequency
14
Vortex Frequency Sensing
14
Measurement Principle of Vortex Flow Meters
14
Flow Velocity Range
15
Pressure Drop
16
Minimum Back Pressure
16
Temperature Measurement
17
Pressure Measurement
17
Flow Meter Configurations
18
Multivariable Options
18
Pro-V™ Vortex Mass Flow Meters
18
Line Size / Process Conditions / Materials
19
Flow Meter Electronics
19
Chapter 2 Installation
21
Installation Overview
21
Flow Meter Installation Requirements
21
Unobstructed Flow Requirements
22
Recommended Meter Locations
23
Series M22 and M24 In-Line Flow Meter Installation
24
Flange Bolt Torquing Sequence
24
Wafer-Style Flow Meter Installation
25
Flange-Style Flow Meter Installation
26
Series M23 Insertion Flow Meter Installation
27
Cold Tap Guidelines
28
Hot Tap Guidelines
29
Hot Tap Sequence
30
Flow Meter Insertion
31
Installing Meters with a Compression Connection
32
Insertion Calculation (Compression Type)
32
Flow Meter with Compression Type Fitting
33
Installing Meters with a Packing Gland Connection
34
Insertion Calculation (Meters with Insertion Tool)
34
Flow Meter with Permanent Insertion Tool
35
Insertion Calculation (Meters Without Insertion Tool)
37
Adjusting Meter Orientation
39
Display/Keypad Adjustment
39
Enclosure Adjustment
40
Loop Power Flow Meter Wiring Connections
41
Input Power Connections
41
DC Power Connections
41
4-20 Ma Output Connections
42
Load Resistance Versus Input Voltage
42
Pulse Output Connections
43
Isolated Pulse Output Using External Power Supply
43
Non-Isolated Pulse Output Using External Power Supply
43
Frequency Output Connections
44
Optional Backlight Connections
44
Isolated Frequency Output Using External Power Supply
44
Remote Electronics Wiring
45
Loop Power Volumetric Flowmeter Junction Box
45
High Power Flow Meter Wiring Connections
47
Input Power Connections
47
DC Power Connections
48
4-20 Ma Output Connections
49
Load Resistance Versus Input Voltage
49
Frequency Output Connections
50
Pulse Output Connections
51
Isolated Frequency Output Using External Power Supply
51
Non-Isolated Frequency Output Using Input Power Supply
51
Isolated Pulse Output Using External Power Supply
52
Non-Isolated Pulse Output Using Input Power Supply
52
Alarm Output Connections
53
Isolated Alarm Output Using External Power Supply
53
Remote Electronics Wiring
54
High Power Flow Meter Junction Box
54
Optional Input Electronics Wiring
55
Optional Energy EMS RTD Input Wiring
55
Optional External 4-20 Ma Input Wiring
56
External 4-20 Ma Input Wiring - External Power Supply
56
External 4-20 Ma Input Wiring - DC Powered Meter
56
External 4-20 Ma Input Wiring - AC Powered Meter
57
Optional Contact Closure Input Wiring
59
Optional External Contact Closure Input Wiring
59
Chapter 3 Operating Instructions
61
Flow Meter Display/Keypad
61
Start up
62
Run Mode Screens
63
Using the Setup Menus
64
Programming the Flow Meter
65
Output Menu
66
Display Menu
68
Alarms Menu
69
Totalizer #1 Menu
70
Totalizer #2 Menu
71
Energy Menu
72
Fluid Menu
73
Units Menu
74
Time and Date Menu
75
Diagnostics Menu
76
Calibration Menu
77
Password Menu
78
Chapter 4 Serial Communications
79
HART Communications
79
Wiring
79
DC Powered Meter Wiring (HART)
80
HART Commands with the DD Menu
81
HART Commands with Generic DD Menu
86
MODBUS Communications
87
Wiring
87
Menu Items
88
Register Definitions
90
Bacnet MSTP Communications
97
1. Bacnet MS/TP Description
97
Baud Rates on the MS/TP Bus
97
Supported Bacnet Objects
98
ANNEX - Bacnet Protocol Implementation Conformance Statement
104
Acronyms and Definitions
110
Chapter 5 Troubleshooting and Repair
111
Hidden Diagnostics Menus
111
Level One Hidden Diagnostics Values
113
Level Two Hidden Diagnostics Values
114
Analog Output Calibration
117
Display Contrast Adjustment
117
Troubleshooting the Flow Meter
118
First Check Items
118
Record Values
118
Determine the Fault
119
Symptom: Output at no Flow
119
Symptom: Erratic Output
119
Electronics Stack Sensor Connections
120
Symptom: no Output
121
Remote Feed through Board Sensor Connections
121
Vortex Sensor Connector
121
Symptom: Meter Displays Temperature Fault
122
Temperature Sensor Connector
122
Symptom: Meter Displays Pressure Fault
123
Pressure Sensor Connector
123
Electronics Assembly Replacement
124
Pressure Sensor Replacement (Series M22 and M24 Only)
125
Returning Equipment to the Factory
125
Appendix A Product Specifications
127
Appendix B Approvals
137
Longmont, CO
138
Appendix C Flow Meter Calculations
141
Appendix D Glossary
147
Advertisement
Advertisement
Related Products
VorTek Pro-V M22
VorTek Pro-V M23
VorTek Pro-V M22 Series
VorTek Pro-V M23 Series
VorTek Pro-V M24 Series
VorTek FlowCalc
VorTek M22 Series
VorTek M23 Series
VorTek MT160
VorTek Pro-V M24
VorTek Categories
Measuring Instruments
More VorTek Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL