Villa Sistemi Medicali STRATO 2000 Digital manual available for free PDF download: Service Manual
Villa Sistemi Medicali STRATO 2000 Digital Service Manual (325 pages)
Brand:
Villa Sistemi Medicali
| Category:
Medical Equipment
| Size: 14 MB
Table of Contents
Table of Contents
4
1 Introduction
8
Icons Appearing in the Manual
9
How to Contact VILLA SISTEMI MEDICALI Technical Service
9
2 Safety Information
10
Warnings
11
Environmental Risks and Displacement
14
Symbols Used
15
3 Description
16
Identification Labels and Laser Labels
16
Function, Models and Version
18
Panoramic Examination
18
Version with Cephalometric Device
18
DXP (Digital Extended Program)
19
Parts Location
20
Location of Electronic Components
22
Block Diagram
23
Power Supply Assembly
24
CPU Board (A1)
25
HF Board (A2) and Tubehead
27
Keyboard
28
Control Panel Descriptions and Functions
31
Key Functions Description
34
Service Programs Description
35
Hardware Configuration Password
35
Service Tools
36
4 Technical Data
38
Applied Safety Regulations
43
Loading Curve of the Tube and Cooling Curve of the Anode
44
Measurement Method of Technical Factors
46
Verify Method of Exposure Parameters
47
Dimensions
51
5 Pre-Installation
54
Electrical Setting up
55
Packaging
57
Space Requirements
58
Version Without CEPH
58
Version with CEPH
59
6 Installation
60
Setting of the Wall
61
Column Mounting
62
Mounting of the Rotating Arm Assembly
65
Mounting of the Chin-Rest Arm
67
Digital Sensor Holder Mounting
68
Mounting of Ceph-Arm (Optional)
69
Mechanical Alignment Check
73
PANORAMIC Alignment Check
73
CEPH Alignment Check
75
How to Mount the Coverings
83
Covering Mounting for the Ceph Arm
84
7 Maintenance and Servicing
86
Verification and Centering Adjustment
88
Axes Alignment for the PANORAMIC Function
88
Centering the RO(Tation), AX (X-Axis) and AY (Y-Axis) Axes Via the Laser
90
Axes Alignment for the CEPH Function
99
CEPH Sensor Centering
100
Ear Centering Circles Setting
100
Rotation Arm Alignment
100
Secondary Collimator Centering
100
Projection of Vertically Non-Concentric Ear Centering Circles
109
Soft Tissue Filter (STF) Adjustment
117
Verify of Kv and Exposure Time
120
Kvp
123
Time
123
Ma Check
124
Storing of Automatical Exposure Parameters
125
Exposure Parameter
125
Soft Tissue Filter
126
Storing Parameters
126
Table of Pre-Set Anatomic Parameters
127
STRATO 2000 Digital Software Utilities
130
8 Troubleshooting
140
Displayed Messages
140
Leds
146
CPU Board LED
147
Board LED
148
Power Supply LED Group
148
Service Programs Descriptions
149
Password 92
151
Password 93
151
Password 89
151
Password 94
152
Password 90
152
Password 95
156
Input Ports Test
157
Keyboard Test
160
ERROR 560: One or more Buttons Pressed at Start-Up
161
During Exam Preparation
163
ERROR 561: X-Ray Button Released During Emission
163
ERROR 562: X-Ray Button Pressed During Start-Up or
163
ERROR 563: Remote X-Ray Button Pressed During
163
Kv / Ma Piloting Circuits Test
164
8.3.6.3.1. ERROR 550: no Voltage Present on HF Board
166
8.3.6.3.2. ERROR 551: Overvoltage
167
8.3.6.3.3. ERROR 552: Overload
168
8.3.6.3.4. ERROR 553: Broken Filament
168
ERROR 554: no X-Ray Output
169
ERROR 555: X-Ray Output too Long
170
Password 102
172
Password 118
172
X-Axis Zero (M5 Motor)
174
Error 500
176
Y-Axis Zero (M4 Motor)
178
Error 501
181
Rotation Axis Zero (M3 Motor)
183
Error 502
186
8.3.8.3.2. ERROR 542: Collision of the Rotating Arm
188
8.3.8.3.3. ERROR 541 / ERROR 543: Panoramic Sensor Holder
188
ERROR 600: Reset Button Pressed During Movement or Exam Preparation
188
Error 504
189
Primary Collimator Motor (M7)
190
8.3.8.5.1. ERROR 580: Zero Sensor Always Darkened
193
ERROR 592: Unexpected Limit Switch Activation
193
ERROR 595: Motor Timeout During Slit Primary
193
Soft Tissue Filter Motor (M6)
195
8.3.8.6.1. ERROR 520: Motor Time out During STF Movement
197
ERROR 522: Limit Switch Not Found / ERROR
197
ERROR 522: Limit Switch Not Found / ERROR 523 Soft Tissue Filter Zero Sensor Always Active
197
Column Motor (Column Test)
199
Password 124
202
Rotation Axis Position
206
Secondary Collimator Motor (M8)
209
ERROR 581 the Zero Sensor of Ceph Secondary Collimator
212
Is Always Active / ERROR 591 Unexpected Limit Switch
212
CEPH Sensor Motor (M9)
214
ERROR 582 the Zero Sensor of Ceph Sensor Is Always
217
Timeout / ERROR 544 CEPH Sensor Motor Limit Sensor Not Found
217
Lining-Up Test
218
Soft Tissue Filter (STF) Offset
219
Soft Tissue Filter (STF) % of Correction
221
Password 130
223
Password 143
223
Memory Errors
226
ERROR 570: Checksum Error on Flash Eprom
226
Error 571-572-573-574-575
226
Generic Errors
227
Error 503
227
Error 506 / 515
227
Error 507
227
Error 601
228
Error 602
228
ERROR 9Xx
228
Search and Correction of Possible Defects in Dental Radiographies
229
Defects Due to Incorrect Position of the Patient
229
Defects Due to Incorrect Radiological Data Input
230
Defects Due to the Unit
231
Analysis of the Problems on the Panoramic Examinations
232
Proper Positioning of the Patient
233
Error Due to a Bad Patient's Positioning
235
Images with Artefacts
243
9 Schematics and Drawings
246
10 Spare Parts
301
11 Fixing Template
319
12 Appendix
321
Appendix A: Setup Parameters Table
321
Appendix B: Installation Checklist
323
Advertisement
Advertisement
Related Products
Villa Sistemi Medicali Arcovis 3000
Villa Sistemi Medicali ENDOS AC
Villa Sistemi Medicali ENDOS ACP