Vertiv Liebert ITA2-08KRT208C Manuals
Manuals and User Guides for Vertiv Liebert ITA2-08KRT208C. We have
1
Vertiv Liebert ITA2-08KRT208C manual available for free PDF download: User Manual
Vertiv Liebert ITA2-08KRT208C User Manual (74 pages)
8-10kVA, 60Hz, 208/220V Three-Phase UPS
Brand:
Vertiv
| Category:
UPS
| Size: 35.21 MB
Table of Contents
Table of Contents
3
Important Safety Instructions
7
Save These Instructions
7
1 Introduction
10
Features
10
Model Configurations
10
Appearance and Components
11
Components-Front Panel
11
Components-Rear Panel
11
Figure 1 UPS Front Panel
11
Major Components
12
Figure 2 UPS Rear Panel
12
Figure 3 UPS Operating Principle
12
Battery Cabinets
13
DC-DC Charger
13
Inverter
13
Rectifier/Power Factor Correction (PFC) Circuit
13
Static Bypass Switch
13
Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters
13
UPS State and Operation Mode
13
Normal Mode
14
Figure 4 Normal Mode
14
Bypass Mode
15
Battery Mode
15
Figure 5 Bypass Mode
15
Auto Restart Mode
16
Eco Mode-Single UPS
16
Fault State
16
Figure 6 Battery Mode
16
Maintenance Bypass Mode
17
Figure 7 Maintenance Bypass Mode
17
2 Single Ups Installation and Commissioning
18
Unpacking and Inspection
18
Moving the UPS
19
Figure 8 Unpacking Cardboard Box
19
Installation Preparation
20
Location
20
Environmental Requirements
20
Figure 9 Installation Clearances
20
Installation Tools
21
External Protective Devices
21
Rectifier and Bypass Input
21
Battery Input
22
UPS Output
22
Mechanical Installation
22
Tower Installation
22
Figure 10 RCCB Symbols
22
Figure 11 Connecting the Support Base with Support Base Extension
23
Figure 12 Assemble the Support Base for UPS and Battery Cabinets
23
Figure 13 UPS and Battery Cabinet Installation Complete
23
Rack Installation
24
Figure 14 Installing Brackets
24
Figure 15 Guide Rail and Screw
24
Figure 16 Installing the Guide Rail
25
Figure 17 Guide Rails Installed
25
Connecting Power Cables
26
Figure 18 Installing the UPS
26
Table 2 Currents and Wire Size-UPS Rectifier Input, Single-Source Configuration
26
Connecting I/O Cables
27
Figure 19 Input/Output Cable Terminals
27
Table 3 AC Currents and Cables-UPS Bypass Input* and Output
27
Single-Input Configuration
28
Dual-Input Configuration
29
Figure 20 Wiring Diagram-Single-Input Configuration
29
Connecting Battery Cables
31
Figure 21 Wiring Diagram-Dual Input Configuration
31
Figure 22 Battery Insulating Plate
32
Figure 23 Cables between Liebert ITA2 and Battery Cabinets
33
Figure 24 Cable the UPS to Two Battery Strings in Parallel
34
3 Operation and Display Panel
35
Figure 25 Operation and Display Panel
35
LED Indicators
36
Audible Alarm (Buzzer)
36
LCD and Function Keys
36
Table 7 Audible Alarm Description
36
LCD Menu Structure
37
Figure 26 LCD Screen
37
Figure 27 LCD Menu Structure
37
LCD Screen Types
38
Start Screen
38
UPS MIMIC Screen
38
Figure 28 Start Screen
38
Figure 29 UPS MIMIC
38
Main Menu Screen
39
Submenu Screen
39
Figure 30 Main Menu Screen
39
Figure 31 Status Page Menus
40
Figure 32 Settings Page Password
41
Figure 33 Settings Page Menus
41
Figure 34 Settings Page Menus-Continued
42
Figure 35 Control Page Menus
43
Figure 36 Log Screen Menus
43
Figure 37 about Screen Menus
44
Figure 38 Maintain Screen-Password Required
44
Language Selection
45
Changing Current Date and Time
45
Figure 39 Monitor Interface
45
Setting the Password
46
Figure 40 Changing Date and Time
46
Figure 41 Entering Password
46
Figure 42 Monitor Interface-Change Settings Password
47
Figure 43 Password for Settings
47
Figure 44 Confirm New Password
47
Figure 45 Password Confirmation Incorrect, Password Change Failed
48
LCD Parameter Settings
48
Default Screen
51
Figure 46 Default Screen
51
4 Operating Instructions
52
UPS Startup
52
Initial Startup Guide
52
Figure 47 Initial Startup Guidance
52
Figure 48 Initial Startup Guidance
53
Figure 49 Initial Startup Guidance
53
Figure 50 Initial Startup Guidance
53
Transfer between Operation Modes
54
Transfer from Inverter Mode to Bypass Mode
54
Figure 51 Initial Startup Guidance
54
Figure 52 Bypass Normal Interface
54
Transfer from Bypass Mode to Inverter Mode
55
Figure 53 Bypass Abnormal Interface
55
Figure 54 Transfer to Inverter Mode from Bypass Mode
55
Repo
56
Figure 55 Eco Mode Enabled Interface
56
5 Communication
57
Liebert Intellislot Port
57
Liebert IS-UNITY-DP Card
57
Liebert IS-Relay Card
57
Figure 56 Liebert Intellislot Card Location
57
Connection Cables for Dry Contact Port
58
Figure 57 Pin Layout of Dry Contact Ports
58
Table 10 Dry Contact Port Descriptions
58
Connecting USB Communication Cables
59
Connecting Serial Port Communication Cables
59
Figure 58 REPO Cable Connections
59
Connecting Multifunction Port
60
Table 11 DB-9 Pinout
60
6 Maintenance
61
Battery Maintenance
61
Cleaning the UPS
61
7 Options
62
Battery Cabinet Appearance
62
Figure 59 Battery Cabinet
62
Table 12 Option List
62
Standard Battery Cabinet Backup Time with a Single UPS
63
Table 13 Backup Time in Minutes-8Kva/7.2Kw
63
Table 14 Backup Time in Minutes-10Kva/10Kw
63
8 Specifications
64
Table 15 Specifications
64
Appendix A - Ups Prompts and Alarms
66
Prompt Window
66
UPS Alarm Message List
66
Table 16 UPS Prompts and Meanings
66
Table 17 UPS Alarm Messages
66
Advertisement
Advertisement
Related Products
Vertiv Liebert ITA2-08KRT208
Vertiv Liebert ITA2
Vertiv LIEBERT ITA2 MBC
Vertiv Liebert ITA2-10KRT208C
Vertiv Liebert ITA2-10KRT208
Vertiv Liebert ITA2 30kVA
Vertiv Liebert ITA2 1-3kVA
Vertiv ITA-30k00AL3302P00
Vertiv Liebert ITA-01k00AS1102C00
Vertiv Liebert ITA-01k00AL1102C00
Vertiv Categories
UPS
Power Supply
Switch
Power distribution unit
Air Conditioner
More Vertiv Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL