Sign In
Upload
Manuals
Brands
VATECH Manuals
DC Drives
pDRIVE CX profi
VATECH pDRIVE CX profi Frequency Inverter Manuals
Manuals and User Guides for VATECH pDRIVE CX profi Frequency Inverter. We have
1
VATECH pDRIVE CX profi Frequency Inverter manual available for free PDF download: Operating And Mounting Instructions Manual
VATECH pDRIVE CX profi Operating And Mounting Instructions Manual (112 pages)
Brand:
VATECH
| Category:
DC Drives
| Size: 1.78 MB
Table of Contents
Automatic Restart
2
Delivery Conditions
2
Parameters
2
Safety Instructions
2
Specifications
2
Operating and Mounting the Frequency Inverter
3
Description of the Control Panel
4
Displays
4
Operating Using the Control Panel Built-In
4
Quick Navigation and Adjustment of Parameters
4
Example of Programming to Set the Frequency and to Start the Inverter
5
Mounting
5
Alarm-LED
6
Hz-LED
6
Leds on the Control Panel
6
Power-LED
6
Overview of Control Levels
7
Changing Parameter Settings on the 1St Control Level
8
Changing Parameter Settings on the 2Nd Control Level
8
Changing the Indication of the LED Display
8
Overview of Parameters
9
Parameter Name
9
Analog Inputs
10
Multispeeds
10
Parameter Name
10
DC Brake
11
Parameter Name
11
V/F Characteristic
11
Automatic Voltage Regulation
12
Frequency Limits
12
Parameter Name
12
PID Configuration
12
Ramp Adjustment
12
Digital Inputs
13
Overload Protection
13
Parameter Name
13
Thermal Protection
13
Table of Contents
14
Digital Outputs
14
General Functions
14
Output Functions
14
Undervoltage / Autoreset
14
2Nd Set
15
Analog Outputs
15
Energy Saving
15
Fault Memory
16
Option Cards
16
Serial Communication
16
Software Lock, Factory Default
16
Before Working with the Equipment Check Following Points
17
Commissioning
17
Commissioning Via the Built-In Keypad
17
Factory Defalut (Initialisation)
17
Description of Parameters
18
Jogging Frequency
18
Output Current
18
Output Frequency
18
Condition of Digital Inputs
19
Condition of Digital Outputs
19
Output Frequency Scaled
19
Output Voltage
19
1St Acceleration Ramp
20
Base Frequency
20
Base Settings
20
Maximum Frequency
20
External Frequency Start O (0...10V)
21
External Frequency Start OI (4...20Ma)
21
Method of Run Command
21
Method of Speed Command
21
Ext. Frequency Start Pattern OI (4...20Ma)
22
External Frequency Start Pattern O (0...10V)
22
AT Terminal Selection
23
O2 Control Selection
23
Time Constant for Analog Signals
23
Multi Speed Selection
24
Multi Speeds − “Binary” Function
25
Multispeeds − “Bit” Function
25
Stop Mode of Jog Function
25
Manual Torque Boost Frequency Point
26
Manual Torque Boost Setting
26
Torque Boost Method Selection
26
V/F Characteristic Setting
26
Start Reduced Voltage Selection
27
Voltage Gain Setting
27
Free Adjustable V/F Characteristic
28
Selection of DC Braking
28
DC Brake Always Active (A051=01)
29
DC Brake Depending on Contact
29
DC Brake Depending on Time
29
DC Brake Controlled Via Digital Input (A051=00)
30
Dynamic Braking ON-Level
31
Dynamic Braking Ratio
31
Dynamic Braking Selection
31
Frequency Upper Limit
31
1St Jump Frequency
32
1St Jump Frequency Width
32
3Rd Jump Frequency Width
32
General
32
Actual Value
33
Displays
33
PID Reference Value
33
PID Controller: Differential Gain(Tv)
34
PID Controller: Integral Gain(Tn)
34
PID Controller: Proportional Gain (Kp)
34
Selection of PID Function: ON/OFF
34
PID Controller: Feedback Destination
35
PID Controller: Level of Deviation
35
PID Controller: Scale Conversion
35
2Nd Acceleration Ramp
36
2Nd Deceleration Ramp
36
Selection of AVR Function
36
Selection of Voltage for AVR
36
Pattern of Acceleration Ramp
37
Pattern of Deceleration Ramp
37
Switch-Over 1./2. Acceleration Ramp
37
Switch-Over 1./2. Deceleration Ramp
37
Electronic Overload Characteristic
38
Electronic Overload Setting
38
Free Electronic Thermal: Current 1
38
Free Electronic Thermal: Frequency 1
38
Level of 1St Overload Restriction
39
Rate of 1St Decel. at Overload Restriction
39
Selection of 1St Overload Restriction
39
Selection of 2Nd Overload Restriction
39
Explanations of the Functions for the Digital Inputs
41
Jog Mode
41
Multispeeds (“Binary” Function)
41
Start/Stop Via Switch Contacts
41
Impulse Lock
42
Switch-Over of Parameters
42
Switch-Over of Ramps
42
External Fault
43
Restart Lock for Undervoltage (USP)
43
Bypass Signal
44
Software Lock
44
Switch-Over to Automatic Reference Value
44
External Reset
45
Motorpotentiometer
45
PID Controller
45
Start/Stop Via Impulses
45
Multispeeds (“Bit”-Function)
46
Switch-Over of Overload Restriction
46
Reference Up/Down Selecteion
47
Standardization of Thermistor Input
47
Thermistor Error Level
47
Thermistor Type Seleciton
47
C021 Function of Relay
48
Function of Relay 11
48
Function of Relay 12
48
Function of Relay al
48
C032 Relay Output
50
Relay Output 11: Inversion
50
Relay Output 12: Inversion
50
Relay Output AL: Inversion
50
Arrival Signal for Acceleration 1
51
Arrival Signal for Deceleration 1
51
Level of Overload Signal 1
51
Overload Signal Output Mode
51
Level of Thermal Motor Protection
52
Retry Waiting Time
52
Run/Power on Time
52
Sec 1,0 Sec
52
Selection of Restart Mode
52
Input Phase Loss Protection
53
Matching Frequency Setting
53
Undervoltage Number of Retry
53
Undervoltage Trip During Stop
53
Carrier Frequency Setting
54
Direction Restriciton (Input)
54
Frequency Converted Value Setting
54
Start Frequency Adjustment
54
Cooling Fan Control
55
Display Selection
55
Motor Kw Rating
55
Motor Poles
55
2Nd Frequency Lower Limit
56
2Nd Internal Pre-Set Speed
56
2Nd Torque Boost Method Selection
56
2Nd V/F Characteristic Setting
56
2Nd Electronic Overload Setting
57
2Nd Selection of Electronic Overload Charact.
57
2Nd Stage Acceleration Change over Point
57
2Nd Stage Deceleration Change over Point
57
Function of am Analog Output
58
Function of AMI Analog Output
58
Function of FM PWM Output
58
AM Analog Adjustment
59
AM Analog Offset
59
AMI Analog Offset
59
FM PWM Meter Adjustment
59
Number of Trips
63
Trip Messages
63
Error Messages
64
Alarm Messages
67
Warning Monitor
67
Further Displays
68
Frequencies > 60 Hz
69
Short Mains Failure
69
Special Safety Instructions
69
Braking Function
70
General Data
70
Power Data
70
Technical Data
70
General Technical Data
71
Mains Impedance
72
Remarks on Power Supply
72
Safety Remarks / FI Safety Switch
72
Key to Table
73
Mains Fuses and Cable Diameters
73
Compensation Capacitors
74
Motor Cable Lengths
74
Option: AMF (Output Motor Filter)
74
Remarks to the Inverter Output Side
74
Distances from Other Devices or against the Wall
75
General Mounting Information
75
Dimensions
76
Power Connections
79
General Connecting Information
80
Control Terminals
81
External Wiring
81
Internal Wiring of the Control Terminals
81
Specification of Control Terminals
82
Manual Operation Via the Built-In Keypad
85
Wiring Examples
85
Operation Via Analogue Reference Value 0...10 V
86
Operation Via Analog Reference Value 4...20 Ma
87
Operation Via Multispeeds
88
Control Diagram
89
Operation Via Integrated PID Controller
89
Setting Example: Flow Control
89
Parameter Adjustments
90
Reference Value
90
Installation Rules
92
Line Choke (Built-In into the CE-DR RFI-Filter)
92
Protective Measure FI Safety Switch
92
RFI-Filters CE-DR
92
Allocation Table: Inverter - Options - Motor Cables - Motor
94
Mains Voltage
95
Wiring
95
Wiring Diagram
95
Mounting and Connection
96
AMF Specification
97
Output-Motor-Filter AMF
97
Amf 450/12:
98
Amf 450/48:
98
Amf 450/90:
98
Overtemperature Protection
99
Isolated Amplifier TV5, TV6
100
EMC Product Standard for PDS (Power-Drive-Systems) en 61800-3
101
BDM: Base-Drive-Module
102
CDM: Complete-Drive-Module
102
PDS: Power-Drive-System
102
Domestic Premises
103
Industrial Premises
103
Frequency Inverters
104
Start-Up Log
104
Advertisement
Advertisement
Related Products
Vatech PaX-i3D Smart
VATECH PaX-i3D Green
VATECH PHT-60CFO
Vatech PaX-i Plus
Vatech PaX-500
Vatech PaX-i Plus PCH-30CS
Vatech PHT-30CSS
Vatech PHT-65LHS
Vatech PaX-Reve3D
Vatech Premium PAX-i3D
VATECH Categories
Medical Equipment
Dental equipment
Diagnostic Equipment
Accessories
DC Drives
More VATECH Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL