Sign In
Upload
Manuals
Brands
Vaisala Manuals
Transmitter
WINDCAP WMT52
Vaisala WINDCAP WMT52 Manuals
Manuals and User Guides for Vaisala WINDCAP WMT52. We have
2
Vaisala WINDCAP WMT52 manuals available for free PDF download: User Manual, Technical Reference Manual
Vaisala WINDCAP WMT52 User Manual (143 pages)
Ultrasonic Wind Sensor
Brand:
Vaisala
| Category:
Accessories
| Size: 2.8 MB
Table of Contents
Table of Contents
3
Chapter 1 General Information
11
About this Manual
11
Contents of this Manual
11
General Safety Considerations
12
Feedback
13
ESD Protection
13
Recycling
13
Trademarks
14
License Agreement
14
Regulatory Compliance
14
Warranty
15
Chapter 2 Product Overview
17
Introduction to Ultrasonic Wind Sensor WMT52
17
Figure 1 Ultrasonic Wind Sensor WMT52
17
Heating Function
18
Optional Software for Easy Settings
18
Ultrasonic Wind Sensor WMT52 Components
19
Figure 2 WMT52 Components
19
Figure 3 Bottom of the Sensor
20
Figure 4 Mounting Kit (Optional)
21
Figure 5 USB Cables (Optional)
21
Figure 6 Bird Spike Kit (Optional)
22
Figure 7 Surge Protector (Optional)
23
Chapter 3 Functional Description
25
Wind Measurement Principle
25
Heating (Optional)
27
Figure 8 Heating Control
27
Chapter 4 Installation
29
Unpacking Instructions
29
Selecting the Location
30
Figure 9 Recommended Mast Location in an Open Area
30
Figure 10 Recommended Mast Length on Top of a Building
31
Installation Procedure
32
Mounting
32
Mounting to Vertical Pole Mast
32
Mounting with Optional Mounting Kit
33
Figure 11 Location of Fixing Screw
33
Mounting to Horizontal Cross Arm
34
Figure 12 Mounting WMT52 to Pole Mast Using Optional Mounting Kit
34
Figure 13 Mounting WMT52 to Cross Arm
35
Figure 14 Mounting Bolt Location in Cross Arm
35
Grounding the WMT52
36
Grounding Using the Bushing and Grounding Kit
36
Figure 15 Grounding Using the Bushing and Grounding Kit
36
Marine Grounding Jumper
37
Figure 16 Grounding Jumper Location
37
Aligning the WMT52
38
Compass Alignment
38
Figure 17 Sketch of Magnetic Declination
38
Wind Direction Offset
39
Figure 18 Wind Direction Offset
39
Chapter 5 Wiring and Power Management
41
Power Supplies
41
Operating Voltage
41
Heating Voltage
42
Figure 19 Average Operational Current Consumption
42
Figure 20 Heating Current and Power Vs Vh
43
Wiring Using the 8-Pin M12 Connector
44
External Wiring
44
Figure 21 Pins of 8-Pin M12 Connector
44
Table 1 Pin-Outs for WMT52 Serial Interfaces and Power Supplies
44
Internal Wiring
45
Figure 22 Internal Wiring
45
Chapter 6
45
Wiring Using the Screw Terminals
46
Figure 23 Screw Terminal Block
46
Data Communication Interfaces
48
Figure 24 Data Communication Interfaces
48
Power Management
49
Chapter 6 Connection Options
53
Communication Protocols
53
Table 3 Available Serial Communication Protocols
53
Connection Cables
54
Table 4 Connection Cable Options
54
Installing the Driver for the USB Cable
55
Service Cable Connection
56
Connection through M12 Bottom Connector or Screw Terminal
57
Table 5 Default Serial Communication Settings for M12/Screw Terminal Connection
57
Communication Setting Commands
58
Checking the Current Communication Settings (Axu)
58
Setting Fields
59
Changing the Communication Settings (Axu)
61
Chapter 7 Getting the Data Messages
63
General Commands
64
Reset (Axz)
64
Measurement Reset (Axzm)
65
ASCII Protocol
66
Abbreviations and Units
66
Device Address (?)
66
Table 6 Abbreviations and Units
66
Acknowledge Active Command (A)
67
Wind Data Message (Ar1)
68
Supervisor Data Message (Ar5)
69
Combined Data Message (Ar)
70
Composite Data Message Query (Ar0)
70
Polling with CRC
71
Automatic Mode
72
Automatic Composite Data Message (Ar0)
73
SDI-12 Protocol
73
Address Query Command (?)
74
Acknowledge Active Command (A)
75
Change Address Command (Aab)
75
Send Identification Command (Ai)
76
Start Measurement Command (Am)
77
Start Measurement Command with CRC (Amc)
78
Start Concurrent Measurement (Ac)
78
Start Concurrent Measurement with CRC (Acc)
79
Send Data Command (Ad)
80
Examples of Am, Ac and Ad Commands
81
Continuous Measurement (Ar)
82
Continuous Measurement with CRC (Arc)
83
Start Verification Command (Av)
83
NMEA 0183 V3.0 Protocol
84
Device Address (?)
84
Acknowledge Active Command (A)
85
MWV Wind Speed and Direction Query
85
XDR Transducer Measurement Query
87
Table 7 Transducer Ids of the Measurement Parameters
89
TXT Text Transmission
93
Table 8 Transducer Table
93
Automatic Mode
94
Automatic Composite Data Message (Ar0)
95
Chapter 8 Sensor and Data Message Settings
97
Wind Sensor
97
Checking the Settings (Awu)
97
Setting Fields
99
Changing the Settings (Awu)
101
Supervisor Message
103
Checking the Settings (Asu)
103
Setting Fields
104
Changing the Settings (Asu)
105
Composite Data Message (Ar0)
106
Chapter 9 Maintenance
109
Cleaning
109
Factory Calibration and Repair Service
110
Vaisala Service Centers
110
Chapter 10 Troubleshooting
111
Table 9 Data Validation
111
Table 10 Communication Problems
112
Self-Diagnostics
113
Error Messaging/Text Messages
113
Table 11 Error Messaging/Text Messages Table
114
Wind Sensor Heating Control
115
Operating Voltage Control
115
Technical Support
115
Chapter 11 Technical Specifications
117
Specifications
117
Table 12 Performance
117
Table 13 Inputs and Outputs
118
Table 14 Operating Conditions
118
Table 15 Electromagnetic Compatibility
119
Table 16 Materials
119
Table 17 General
119
Options and Accessories
120
Table 18 Options and Accessories
120
Dimensions
121
Figure 25 WMT52 Dimensions in MM (Inch)
121
Figure 26 Mounting Kit Dimensions in MM (Inch)
122
Appendix Anetworking
123
Connecting Several Wmt52S on the same Bus
123
SDI-12 Serial Interface
123
Wiring
123
Communication Protocol
124
RS-485 Serial Interface
124
Wiring
124
Communication Protocol
125
ASCII, Polled
125
NMEA 0183 V3.0, Query
126
NMEA 0183 V3.0 Query with ASCII Query Commands
128
Appendix B Sdi-12 Protocol
131
SDI-12 Electrical Interface
131
SDI-12 Communications Protocol
132
SDI-12 Timing
133
Figure 27 SDI-12 Timing Diagram
133
Appendix C Crc-16 Computation
135
Encoding the CRC as ASCII Characters
136
NMEA 0183 V3.0 Checksum Computation
136
Appendix D
137
Wind Measurement Averaging Method
137
Figure 28 Wind Measurement Averaging Method
138
Appendix E Factory Configurations
139
Factory Configurations
139
General Unit Settings
140
Wind Configuration Settings
140
Table 19 General Unit Settings
140
Table 20 Wind Configuration Settings
140
Supervisor Settings
141
Table 21 General Unit Settings
141
Advertisement
Vaisala WINDCAP WMT52 Technical Reference Manual (20 pages)
BACnet Protocol Information Conformance Statement
Brand:
Vaisala
| Category:
Transmitter
| Size: 0.34 MB
Table of Contents
Table of Contents
3
Chapter 1 General Information
4
About this Manual
4
Version Information
4
Related Manuals
4
Chapter 2 Bacnet Reference
5
Bacnet Protocol Implementation Conformance Statement
5
Device Object
8
Object_Identifier
9
Object_Name
9
System_Status
9
Protocol_Services
10
Database_Revision
10
Relative Humidity Object
10
Status Flags
11
Reliability
11
Event State
11
Out of Service
11
Temperature Object
12
Units
12
Status Flags
12
Reliability
13
Event State
13
Out of Service
13
Calculated Humidity Objects
14
Status Flags
15
Reliability
15
Event State
15
Out of Service
15
Operation Pressure Object
16
Present Value
16
Status Flags
16
Event State
16
Out of Service
16
Operation Altitude Object
17
Present Value
17
Units
17
Status Flags
17
Event State
17
Out of Service
17
Bibbs Supported
18
Application Services Supported
19
Advertisement
Related Products
Vaisala WXT520
Vaisala WXT510
Vaisala WAC155
Vaisala WAT12
Vaisala WS425 F/G
Vaisala WXT536
Vaisala WXT532
Vaisala WXT535
Vaisala WXT534
Vaisala WXT531
Vaisala Categories
Transmitter
Measuring Instruments
Accessories
Test Equipment
Weather Station
More Vaisala Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL