Sign In
Upload
Manuals
Brands
Vaisala Manuals
Multimeter
HUMICAP MM70
Vaisala HUMICAP MM70 Manuals
Manuals and User Guides for Vaisala HUMICAP MM70. We have
1
Vaisala HUMICAP MM70 manual available for free PDF download: User Manual
Vaisala HUMICAP MM70 User Manual (71 pages)
Hand-Held Moisture and Temperature in Oil Meter
Brand:
Vaisala
| Category:
Multimeter
| Size: 3 MB
Table of Contents
Table of Contents
3
Chapter 1 General Information
7
About this Manual
7
Product Related Safety Precautions
7
ESD Protection
7
Recycling
8
Trademarks
8
License Agreement
8
Warranty
9
Chapter 2 Product Overview and Mechanics
11
Vaisala´s Hand-Held MM70 Device
11
Structure of the MI70 Indicator
12
Figure 1 MI Indicator
12
Structure of the MMP78 Probe
13
Tools
13
Figure 2 MMP78 Probe
13
Figure 3 Protecting Cap and Plastic Wrench
13
Display Parameters
14
Options
14
Chapter 3 Installation and Mounting Options
15
Installing and Recharging the Batteries
15
Turning on the Device
15
Installing the Probe
16
Mounting the Probe for Pressurized Pipelines/Oils
16
Tightening the Clasp Nut
17
Figure 4 MMP78 Pipe Dimensions (in MM); 400 MM
17
Figure 5 Tightening Clasp Nut
18
Ball Valve Installation
19
Figure 6 Sealing Thread Cutting for the Fitting Body
19
Figure 7 Ball Valve Installation
20
Mounting the Probe for Direct Measurement (no Pressure)
21
Figure 8 Direct Mounting
21
Chapter 4 Menu Operations and Settings
23
Function Keys and Menu Structure
23
Navigating in Menu
23
Figure 9 Keypad
23
Basic Display
24
Figure 10 Basic Display
24
Graphical Display
25
Main Menu
25
Settings
26
Display Settings
26
Quantities and Units
26
Rounding
26
Figure 11 Display Setting Menus
26
Hold/Save Display
27
Graphic History
27
User Interface Settings
28
Figure 12 User Interface Setting Menus
28
Selecting Language
29
Automatic Power off
29
Changing the Shorcut Keys
30
Turning Key Click and Backlight On/Off
30
Setting Date and Time
30
Device Information
31
Figure 13 Device Information Setting Menus
31
Restoring Factory Settings
32
PPM-Calculation
32
Figure 14 Device Information Submenus
32
Calculation Model with Oil Specific Coefficients
33
Feeding the Coefficients to the MI70 Memory
33
Other Functions
34
Setting the Alarm Levels
34
Figure 15 Measurement Setting Menus
34
Figure 16 Alarm Function Menus
34
Selecting and Scaling the Analog Output
36
Figure 17 Analog Output Menus
36
Taking Measurements
37
Measuring Other Parameters Simultaneously
37
Recording Data
38
Recording
38
Figure 18 Record and View Menu
38
Stopping Recording
39
Table 1 Measurement Intervals and Max. Recording Times
39
Viewing Recorded Data
40
Checking the Memory Status
40
Deleting All Recorded Files
40
Transferring Recorded Data to PC
41
Chapter 5 Calibration and Adjustment
43
General Notes about Calibration and Adjustment of Transmitters
43
Using MM70 in Checking and Adjusting
43
Using Calibration Cables
43
Calibration and Adjustment of HMP228 Series Transmitters
44
Relative Humidity Adjustment by Using a Calibrated Reference Probe
45
1-Point Relative Humidity Adjustment by Using a Calibrator
45
Figure 19 Adjustment Mode
45
2-Point Relative Humidity Adjustment by Using a Calibrator
46
Calibration and Adjustment of MMT318 Transmitters
47
Field Checking and Adjustment by Using a Calibrated Reference Probe
47
1-Point Adjustment by Using a Calibrator
48
2-Point Adjustment by Using a Calibrator
49
Calibration and Adjustment of MMT330 Transmitters
50
Field Checking and Adjustment by Using a Calibrated Reference Probe
50
1-Point Adjustment by Using a Calibrator
51
2-Point Adjustment by Using a Calibrator
52
Calibration and Adjustment of MM70 Series Probes
53
General about Calibrations
53
Preparations before the Calibration
53
Relative Humidity Adjustment
53
Li-Cl-Nacl Automatic Adjustment
53
2-Point Adjustment
54
1-Point Adjustment
55
Temperature Adjustment
55
1-Point Adjustment
56
Last Adjustment Date
57
Determination of Oil-Specific Coefficients
57
Table 2 Example: Measured Water Content 213 Ppm
58
Error Messages
59
Error Message Types
59
Chapter 6 Maintenance
61
Changing the Filter and Sensor
61
Cleaning the Sensor
61
Changing the Battery
62
Figure 20 Installing the Battery Pack
62
Vaisala Service Centers
63
Chapter 7 Technical Specifications
65
Measured Variables
65
Water Activity a W
65
Temperature
65
MMP78 Probe
66
MI70 Indicator
66
Battery Pack
67
General Facts about the MM70 Hand-Held Humidity and Temperature Meter
67
Electromagnetic Compatibility
67
Options and Accessories Available
68
Table 3 List of Options and Accessories
68
Dimensions in MM (Inches)
69
Figure 21 MI70 Indicator
69
Figure 22 MMP78 Probe
70
Advertisement
Advertisement
Related Products
Vaisala Humicap HM40
Vaisala HUMICAP MMT330
Vaisala HUMICAP MMT310
Vaisala HUMICAP MMT162
Vaisala MMP8
Vaisala MW11
Vaisala MOG100
Vaisala MGP260 Series
Vaisala MI70
Vaisala MI
Vaisala Categories
Transmitter
Measuring Instruments
Accessories
Test Equipment
Weather Station
More Vaisala Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL