Manuals and User Guides for TriangleTube CTRLMax Heatmaster Series. We have
1
TriangleTube CTRLMax Heatmaster Series manual available for free PDF download: Supplement Manual
TriangleTube CTRLMax Heatmaster Series Supplement Manual (84 pages)
Brand:
TriangleTube
| Category:
Controller
| Size: 16 MB
Table of Contents
Table of Contents
3
Chapter 1 - Operating Information
9
General
9
PRESTIGE and HEATMASTER Control Panel Description
9
Main Settings of the PRESTIGE and HEATMASTER Ctrlmax Display
9
Fig. 1 - PRESTIGE and HEATMASTER Control Panel
9
1.1.3 INSTINCT Control Panel Description
10
Fig. 2 - INSTINCT Control Panel
10
Main Settings of INSTINCT Ctrlmax Display
11
1.1.5 Main Icons of Ctrlmax Display
11
Installer Access Code
11
Ctrlmax Installer Menu Structure
12
Chapter 2 - Ch Settings
13
Heating Operation
13
Demand Type
13
CH Maximum Capacity
14
CH Minimum Capacity
15
Abs. Max. CH Setpoint
15
CH1 Max. Setpoint
15
CH1 Min. Setpoint
15
Outd. Curve Coldest Day
16
Outd. Curve Warmest Day
16
CH2 Circuit
16
CH2 Max. Setpoint
16
CH2 Min. Setpoint
17
Warm Weather Shutdown
17
Circulation Pump Permanent
17
CH Post Pump Time
17
Freeze Protection
18
Frost Protection Setpoint
18
Parallel Shift Value
19
CH Call Blocking
19
Appliance Min CH Setpoint
19
Chapter 3 - Dhw Settings (Prestige, Heatmaster and Instinct Solo)
21
DHW Operation
21
Demand Type
21
DHW Maximum Capacity
22
DHW Boiler Setpoint
22
DHW Setpoint
22
DHW on Differential
22
DHW Storage Adder
23
DHW Post Pump Time
23
DHW Priority Timeout
23
DHW Priority
23
DHW Call Blocking
24
DHW to CH Call Blocking
24
Antilegionella Function
25
DHW Ramp up
25
Chapter 4 - Dhw Settings (Instinct Combi Only)
27
DHW Operation
27
DHW Maximum Capacity
27
DHW Temp
27
DHW on Differential
28
DHW Warmstart Temperature
28
DHW Warmstart Hysteresis
28
DHW Post Pump Time
28
DHW Priority Timeout
29
DHW Call Blocking
29
DHW to CH Call Blocking
29
DHW Ramp up
29
Chapter 5 - Boiler Settings
31
Model
31
Lockout Temp
31
Modbus Address
31
Pump Settings
32
Preset Pump Config
32
Flexible Pump Config
32
Error Relay
34
Ignition Level
34
MIX Zone High Limit
35
WP Diff Trigger
35
Appliance Setting
35
Altitude
36
Fig. 3 - System Piping with solo Preset Config. 1
37
Fig. 4 - System Pipingwith solo Preset Config. 2
38
Fig. 5 - System Piping with solo Preset Config. 3
39
Fig. 6 - System Piping with solo Preset Config. 4
40
Fig. 7 - System Piping with solo Preset Config.5
41
Fig. 8 - System Piping with solo Preset Config. 6
42
Fig. 9 - System Piping with solo Preset Config. 7
43
Fig. 10 - System Piping with solo Preset Config. 8
44
Fig. 11 - System Piping with solo Preset Config. 9
45
Fig. 12 - System Piping with solo Preset Config. 13
46
Fig. 13 - System Piping with Excellence Preset Config. 1
47
Fig. 14 - System Piping with Excellence Preset Config. 2
48
Fig. 15 - System Piping with Excellence Preset Config. 3
49
Fig. 16 - System Piping with Excellence Preset Config. 4
50
Fig. 17 - INSTINCT solo System Piping - Multi Zone System with Single System/Boiler Circulator
51
Fig. 18 - INSTINCT solo System Piping - Indirect Water Heater Installation
52
Fig. 19 - INSTINCT Combi System Piping - Zoning W Valves
53
Fig. 20 -INSTINCT Combi - System Piping - Multi Zone Valve - Single Circulator
54
Fig. 21 - INSTINCT Combi - System Piping - Single Zone with Single Circulator
55
Fig. 22 - INSTINCT Combi System Piping - Single Zone System with Single System/Boiler Circulator
56
Fig. 23 - INSTINCT Combi System Piping - Domestic Piping - Storage Tank Installation
57
Chapter 6 - Manual Operation
59
Chapter 7 - Reset All Settings
61
Factory Ctrlmax Settings
61
Chapter 8 - Cascade
63
Operating Principles of an Ctrlmax-Controlled Cascade (Prestige and INSTINCT Only)
63
Cascade Algorithm
63
8.2.1 Boiler Enabling Algorithm
63
8.2.2 Boiler Disabling Algorithm
63
Ctrlmax Cascade Menu Structure
64
Cascade Installation
64
8.4.1 System Piping
64
8.4.2 System Sensor Installation
64
8.4.3 Cascade Communication Cable
65
8.4.4 Low Voltage Wiring Connections
65
Fig. 24 - System Sensor Direct Immersion
65
Fig. 25 - System Sensor Dry Well Installation
65
8.4.5 Line Voltage Wiring Connections
66
8.4.6 Cascade Autodetection
66
8.4.7 Lockouts
66
Fig. 26 - Lockouts in a Cascade
66
Cascade Autodetection
67
Cascade Info
68
Cascade Role
68
System Temp
68
Active Boilers
68
Total Boilers
68
Cascade Firing Ratio
68
Cascade Settings
69
Stage Delay
69
Min. Firing Rate
70
Max. Firing Rate
70
CH / DHW Boilers
70
Auto Rotation
72
CH Prop. Gain
72
CH Integral Gain
73
DHW Prop. Gain
74
DHW Integral Gain
74
Fig. 27 - Primary Secondary Cascade Piping
75
Fig. 28 - Primary Secondary Cascade Wiring
76
Fig. 29 - Reverse Return Cascade Piping
77
Fig. 30 -Reverse Return Cascade Wiring
78
Fig. 31 - Split Cascade System
79
Fig. 32 - Split Cascade Wiring
80
Chapter 9 - Modbus Interface
81
Advertisement
Advertisement
Related Products
TriangleTube CTRLMax Prestige Series
TriangleTube CTRLMax Series
TriangleTube CTRLMax Instinct Series
Triangle Tube CTRLMax Prestige Solo 155
Triangle Tube CTRLMax Prestige Excellence 110
TriangleTube Challenger
TriangleTube IONIC CB 299W
TriangleTube IONIC CB 399W
TriangleTube IONIC CB 1250F
TriangleTube IONIC CB 3000F