Sign In
Upload
Manuals
Brands
TR-Electronic Manuals
Media Converter
CEH582M-8192/4096 EPN DMS 12H7 KRF
TR-Electronic CEH582M-8192/4096 EPN DMS 12H7 KRF Manuals
Manuals and User Guides for TR-Electronic CEH582M-8192/4096 EPN DMS 12H7 KRF. We have
1
TR-Electronic CEH582M-8192/4096 EPN DMS 12H7 KRF manual available for free PDF download: Assembly Instructions Manual
TR-Electronic CEH582M-8192/4096 EPN DMS 12H7 KRF Assembly Instructions Manual (317 pages)
Rotary Encoder construction size 58
Brand:
TR-Electronic
| Category:
Media Converter
| Size: 64 MB
Table of Contents
Deutsch
120
Table of Contents
120
Inhaltsverzeichnis
120
Änderungs-Index
123
Allgemeines
124
Geltungsbereich
124
Referenzen
125
Verwendete Abkürzungen / Begriffe
126
Zusätzliche Sicherheitshinweise
127
Symbol- und Hinweis-Definition
127
Ergänzende Hinweise zur Bestimmungsgemäßen Verwendung
127
Einsatz in Explosionsfähigen Atmosphären
128
Optionale Schnittstellenvarianten
129
PROFINET Informationen
130
Profinet Io
131
Real-Time Kommunikation
132
Weitere Informationen
133
Anschluss - Hinweise
134
Installation / Inbetriebnahmevorbereitung
134
Inbetriebnahme
135
Gerätebeschreibungsdatei (XML)
135
Geräteidentifikation
135
Datenaustausch bei PROFINET IO
136
Adressvergabe
137
Bus-Statusanzeige
138
Version mit Drehschalter
139
Version mit Taster
139
Rückstellung der Netzwerkparameter (Optional)
139
Parametrierung und Konfiguration
140
Modularer Aufbau
140
Übersicht
141
Modul „PNO Encoder Profil
141
Modul „TR Encoder Profil
142
PNO Encoder Profil
143
Aufbau der Zyklischen Prozessdaten
143
Standard Telegram 84
144
Standard Telegram 83
144
Standard Telegram 82
144
Standard Telegram 81
144
Standard Telegram 86
145
Standard Telegram 87
145
Format Signal 6 / 8: Geschwindigkeitswert a / B (NIST_A / B)
146
Format Signal 9: Steuerwort, Sensor 1 (G1_STW)
146
Format Signal 10: Statuswort, Sensor 1 (G1_ZSW)
147
Format Signal 39: Positionswert 3, Sensor 1 (G1_XIST3)
148
Format Signal 12: Positionswert 2, Sensor 1 (G1_XIST2)
148
Format Signal 11: Positionswert 1, Sensor 1 (G1_XIST1)
148
Format Signal 80: Steuerwort 2, Encoder (STW2_ENC)
149
Format Signal 81: Statuswort 2, Encoder (ZSW2_ENC)
149
Format Signal 238: Sensor-Position Preset Steuerwort 32 Bit (G1_XIST_PRESET_A)
150
Parameterzugriff und Initialisierung
151
Konfigurierbare Parameter
152
Drehrichtung
153
Encoder Class 4 Funktionalität
153
Diagnose über Alarmkanal (V3.1)
154
Skalierungsfunktion
154
Preset Beeinflusst XIST1
154
Skalierungsparameter
155
Skalierung: Auflösung Pro Umdrehung (LSB)
155
Kompatibilitätsmodus V3.1
155
Skalierung: Gesamtauflösung (LSB)
156
Tolerierte Lebenszeichenfehler (V3.1)
156
Drehzahlnormierung
157
Geschwindigkeitsreferenzwert N2/N4
157
Parameter Schreibschutz
158
Presetwert 32-Bit
158
Parameter Initialisierung
158
Schreibschutz für Parameter Control (PNU 65005) + Parameter Speichern (PNU 971)
159
Schreibschutz für Parameter Reset (PNU 972)
159
Azyklischer Parameterzugriff (Base-Mode-Parameter-Access - Local)
160
Presetwert 32-Bit (PNU 65000)
163
Betriebsstatus (PNU 65001)
164
Header (PNU 65001.00)
164
Unterstützte Fehler (PNU 65001.03)
165
Fehler (PNU 65001.02)
165
Betriebsstatus (PNU 65001.01)
165
Warnungen (PNU 65001.04)
166
Unterstützte Warnungen (PNU 65001.05)
166
Encoder Profil Version (PNU 65001.06)
166
Offsetwert 32-Bit (PNU 65001.08)
166
Geschwindigkeitsreferenzwert N2/N4 (PNU 65001.12)
167
Drehzahlnormierung (PNU 65001.11)
167
Gesamtauflösung (LSB) (PNU 65001.10)
167
Auflösung Pro Umdrehung (LSB) (PNU 65001.09)
167
Funktionssteuerung (PNU 65004)
168
Parametersteuerung (PNU 65005)
169
Skalierung: Auflösung Pro Umdrehung (PNU 65006)
169
Skalierung: Gesamtauflösung (PNU 65007)
170
Profidrive Bezogene Parameter (PNU 9Xx, 600Xx)
170
Geschwindigkeitsreferenzwert N2/N4 (PNU 60000)
170
Drehzahlnormierung (PNU 60001)
170
Geräte-Identifikation (PNU 964)
171
Tolerierte Master-Lebenszeichenfehler (PNU 925)
171
Telegramm-Auswahl (PNU 922)
171
Profil-Identifikation (PNU 965)
172
Parameter-Speicherung (Dauerhaft) (PNU 971)
172
Geräte-RESET / Parameter-Aktivierung (PNU 972)
172
B M P - Access - Identifikation (PNU 974)
173
Encoder-Objekt-Identifikation (PNU 975)
173
Sensor Format (PNU 979)
174
Parameterliste (PNU 980)
175
Preset-Funktion
176
Warnungen, Fehler, Diagnose
177
Fehlercodes in Signal G1_XIST2
177
PROFINET Diagnose-Alarm
178
TR Encoder Profil
180
TR-Submodul Position
180
Aufbau der Zyklischen Prozessdaten
180
Konfigurierbare Parameter
180
Drehrichtung
181
Skalierungsparameter
181
Geschwindigkeit Format
184
Aufbau der Zyklischen Prozessdaten
184
Konfigurierbare Parameter
184
TR-Submodul Geschwindigkeit
184
Geschwindigkeit Faktor
185
Geschwindigkeit Integrationszeit
185
TR-Submodul Preset (Justage-Funktion)
186
Aufbau der Zyklischen Prozessdaten
186
Justage-Funktion (Azyklischer Zugriff)
187
TR-Submodul Zweitschnittstellenparameter (Optional)
188
SSI Zweitschnittstelle
188
SSI-Ausgabecode
188
SSI-Anzahl Datenbits
188
SSI-Monozeit
189
SSI-Ausgangsdaten
189
SSI-Sonderbit
189
Endschalter
189
Presetschalter
189
Pulses Per Revolution
190
Phase K1/K2
190
Inkremental Zweitschnittstelle
190
K0 Condition
191
Level
191
K0 Length
191
K0 über „TR-Submodul Preset" Setzen
192
TR-Submodul Zustand und Steuerung
192
Aufbau der Zyklischen Prozessdaten
193
PROFINET Diagnose-Alarm
194
Fsu
195
Mrp
195
Medienredundanz (MRP) / Fast Start-Up (FSU)
195
Störungsbeseitigung und Diagnosemöglichkeiten
196
Optische Anzeigen
196
Device-Status LED
196
Net-Status LED
197
Daten-Status
198
Return of Submodul Alarm
198
Information & Maintenance
199
I&M0 - I&M4
199
Sonstige Störungen
201
English
204
Contents
204
Revision Index
207
Applicability
208
General Information
208
References
209
Abbreviations Used / Terminology
210
Additional Instructions for Proper Use
211
Additional Safety Instructions
211
Definition of Symbols and Notes
211
Usage in Explosive Atmospheres
212
Optional Interface Variants
213
PROFINET Information
214
Profinet Io
215
Real-Time Communication
216
Further Information
217
Connection - Notes
218
Installation / Preparation for Commissioning
218
Commissioning
219
Device Description File (XML)
219
Device Identification
219
Data Exchange in PROFINET IO
220
Address Assignment
221
Bus Status Display
222
Resetting of the Network Parameters (Optional)
223
Version with Button
223
Version with Rotary Switches
223
Modular Structure
224
Parameterization and Configuration
224
Overview
225
PNO Encoder Profile" Module
225
TR Encoder Profile" Module
226
PNO Encoder Profile
227
Structure of the Cyclic Process Data
227
Standard Telegram 81
228
Standard Telegram 82
228
Standard Telegram 83
228
Standard Telegram 84
228
Standard Telegram 86
229
Standard Telegram 87
229
Format Signal 6 / 8: Speed Value a / B (NIST_A / B)
230
Format Signal 9: Control Word, Sensor 1 (G1_STW)
230
Format Signal 10: Status Word, Sensor 1 (G1_ZSW)
231
Format Signal 11: Position Value 1, Sensor 1 (G1_XIST1)
232
Format Signal 12: Position Value 2, Sensor 1 (G1_XIST2)
232
Format Signal 39: Position Value 3, Sensor 1 (G1_XIST3)
232
Format Signal 80: Control Word 2, Encoder (STW2_ENC)
233
Format Signal 81: Status Word 2, Encoder (ZSW2_ENC)
233
Format Signal 238: Sensor Position Preset Control Word 32 Bit (G1_XIST_PRESET_A)
234
Parameter Access and Initialization
235
Configurable Parameters
236
Code Sequence
237
Encoder Class 4 Functionality
237
Alarm Channel Control (V3.1)
238
Preset Affects XIST1
238
Scaling Function Control
238
Encoder Profile V3 Compatibility
239
Measuring Units Per Revolution (LSB)
239
Scaling Parameters
239
Tolerated Sign of Life Faults (V3.1)
240
Total Measuring Range (LSB)
240
Velocity Measuring Unit
241
Velocity Reference Value N2/N4
241
Parameter Initialization
242
Parameter Write Protection
242
Preset Value 32 Bit
242
Write Protection for Parameter Control (PNU 65005) + Save Parameter (PNU 971)
243
Write Protection for Parameter Reset (PNU 972)
243
Acyclic Parameter Access (Base Mode Parameter Access - Local)
244
Preset Value 32 Bit (PNU 65000)
247
Header (PNU 65001.00)
248
Operating Status (PNU 65001)
248
Error (PNU 65001.02)
249
Operating Status (PNU 65001.01)
249
Supported Errors (PNU 65001.03)
249
Encoder Profile Version (PNU 65001.06)
250
Offset Value 32-Bit (PNU 65001.08)
250
Supported Warnings (PNU 65001.05)
250
Warnings (PNU 65001.04)
250
Measuring Units Per Revolution (LSB) (PNU 65001.09)
251
Total Measuring Range (LSB) (PNU 65001.10)
251
Velocity Measuring Unit (PNU 65001.11)
251
Velocity Ref Value N2/N4 (PNU 65001.12)
251
Function Control (PNU 65004)
252
Parameter Control (PNU 65005)
253
Scaling: Measuring Units Per Revolution (PNU 65006)
253
Profidrive Related Parameters (PNU 9Xx, 600Xx)
254
Scaling: Total Measuring Range (PNU 65007)
254
Velocity Reference Value N2/N4 (PNU 60000)
254
Velocity Value Normalization (PNU 60001)
254
Device Identification (PNU 964)
255
Telegram Selection (PNU 922)
255
Tolerated Master Sign-Of-Life Faults (PNU 925)
255
Device RESET / Parameter Activation (PNU 972)
256
Parameter Storage (Permanent) (PNU 971)
256
Profile Identification (PNU 965)
256
B M P Access - Identification (PNU 974)
257
Encoder Object Identification (PNU 975)
257
Sensor Format (PNU 979)
258
Parameter List (PNU 980)
259
Preset Function
260
Error Codes in Signal G1_XIST2
261
Warnings, Errors, Diagnosis
261
PROFINET Diagnosis Alarm
262
Configurable Parameters
264
Structure of the Cyclic Process Data
264
TR Encoder Profile
264
TR-Module Position
264
Rotational Direction
265
Scaling Parameters
265
Configurable Parameters
268
Structure of the Cyclic Process Data
268
TR-Module Velocity
268
Velocity Format
268
Velocity Factor
269
Velocity Integration Time
269
Structure of the Cyclic Process Data
270
TR-Module Preset (Adjustment Function)
270
Adjustment Function (Acyclic Access)
271
Secondary Interface SSI Parameters
272
SSI Number of Data Bits
272
SSI Output Code
272
TR-Secondary Interface Parameters (Optional)
272
End Switch Parameters
273
Preset Switch Parameters
273
SSI Mono Time
273
SSI Output Data
273
SSI Special Bit
273
Phase K1/K2
274
Pulses Per Revolution
274
Secondary Incremental Interface
274
K0 Condition
275
K0 Length
275
Level
275
Set K0 by Means of "TR-Module Preset
276
TR-Module Status and Control
276
Structure of the Cyclic Process Data
277
PROFINET Diagnosis Alarm
278
Fsu
279
Media Redundancy (MRP) / Fast Start-Up (FSU)
279
Mrp
279
Device Status LED
280
Optical Displays
280
Troubleshooting and Diagnosis Options
280
Net Status LED
281
Data Status
282
Return of Submodule Alarm
282
I&M0 - I&M4
283
Information & Maintenance
283
Miscellaneous Faults
285
Advertisement
Advertisement
Related Products
TR-Electronic CEH582M-8192/32768 EPN DMS 12H7 KRF
TR Electronic CEH-58
TR-Electronic CEH-110
TR-Electronic CEH-80
TR Electronic CEH-1102
TR-Electronic CEH1102M 8192/4096 ETC DMS 40H7NUT KRH
TR-Electronic CEH110M 4096/4096 SSI DMS 30H7NT KRH
TR-Electronic CEH110M-8192/4096 EPN DMS 28H7/N KRH
TR-Electronic CEH80S-8192/1 V000 SSI HW16H7
TR-Electronic CEH802M-8192/4096 SSI NTS 25H7N KRF
TR-Electronic Categories
Media Converter
Transducer
Measuring Instruments
Enclosure
DC Drives
More TR-Electronic Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL