Sign In
Upload
Manuals
Brands
Thunder Scientific Manuals
Measuring Instruments
1220
Thunder Scientific 1220 Manuals
Manuals and User Guides for Thunder Scientific 1220. We have
2
Thunder Scientific 1220 manuals available for free PDF download: Operation And Maintenance Manual, Quick Start Manual
Thunder Scientific 1220 Operation And Maintenance Manual (318 pages)
Humidity Generation System
Brand:
Thunder Scientific
| Category:
Laboratory Equipment
| Size: 38 MB
Table of Contents
Important Notice
4
Table of Contents
8
Getting Started
13
About
13
Notice
14
Safety Information
14
Live Power Source
14
Electrostatic Discharge
14
Compressed Gas
14
Personal Protective Equipment
14
Safety Symbols
15
Technical Support
15
License Agreement
15
Warranty
17
Copyright
17
Trademarks
17
Specifications
18
Uncertainty
19
Facility Requirements
20
Environment
20
Floor or Bench Space
20
Air Supply
20
Reservoir Distilled Water Supply
20
Installation
21
Uncrating
21
Positioning
21
Chamber Fluid
21
Reservoir Initial Filling Procedure
22
Setting Supply Pressure Regulator
22
Quick Start
23
Power-Up
23
Loading Screen
24
Controlog Screen
25
Control Parameters
26
Control Modes
30
Generating and Shutting down
31
Power-Off
32
Date and Time or Point Time
33
Set Date and Time
33
Help
34
Expansion Valve (T Exv )
35
Pre-Saturation (T Psat )
35
Principle of Operation
35
Saturation Temperature (T Chamber Temperature (T C )
36
Saturation Temperature (T )
36
Saturation Pressure (P S )
36
Chamber Pressure (P C )
36
Humidity Formulas
36
Controlog Interface
37
Menu Bar
38
File Menu Tab
39
Home Menu Tab
43
Units Menu Tab
46
Operation Menu Tab
47
Profile Menu Tab
50
Utilities Menu Tab
52
Graph Menu Tab
56
Data Menu Tab
58
Device Settings Menu Tab
62
Help
64
Parameters Tab Group
65
Tiles
67
1220 Parameter Tab
70
Device Parameter Tabs
74
Data and Graph Tab Group
75
Data Tabs
76
Graph Tabs
76
Profile Tab
76
Information Tab Group
76
Status Log
78
1220 Reported Warnings & Errors
79
System Timing
79
1220 Interface Console
80
Device Interface Console
80
Status Bar
81
Connection and Run Status
81
Auto Profile Controls and Status
82
Current Date and Time or Point Time
83
Set Date and Time
83
Fluid Levels
85
Water Reservoir Level
85
Fill Water Reservoir
86
Liquid Level Sensors
87
Pre-Saturator Level
87
Fluid Pump
88
Calibration
89
Temperature Calibration
89
Equipment Required
90
Calibration Procedure
90
Pressure Transducer Calibration
105
Equipment Required
105
Calibration Procedure
105
Supply Pressure
120
Mass Flow Meter Calibration
121
Equipment Required
121
Calibration Procedure
121
Viewing and Editing Calibration Coefficients
135
Coefficient Calculator
138
Graphing
141
Creating a New Graph
142
Line Properties
145
Chart Properties
145
Customizing a Graph
146
Pan
146
Zoom
147
Zoom Graph's X Axis
148
Zoom Graph's y Axis
149
Auto Scale
149
Scale
149
Scale X Axis
149
Scale y Axis
149
Graph Properties
150
Saving a Graph
152
Data and Data Summary
154
Device Data Tabs
158
File Data Tabs
159
Data Summary Tabs
162
Creating a Data Summary
163
Recorded Data Points Tab
170
How to Record a Data Point
171
Auto Profiling
176
Creating a New Profile
178
Saving a Profile
186
Opening a Profile
188
Running an Auto Profile
190
Understanding Profile Phases
192
Manual Override of Profile
195
Connections
197
Serial Connection
198
Serial Connection Example 1
213
Serial Connection Example 2
225
Analog Connection
242
Analog Connection Example
252
Manual Connection
261
Manual Connection Example
265
Opening a Device Connection
274
External Control
274
Data Backup
275
System
276
Control System
276
Data Acquisition Chassis
276
HMI Computer
276
Controlog® Software
277
Humicalc with Uncertainty ® Software
278
Electrical System
278
Solid State Relays
279
Thermoelectric Controller
279
Pneumatic System
280
Pressure Measurement
280
Mass Flow Rate Measurement
280
Pre-Saturator
281
Reservoir
281
Saturator
281
Flow Control Valve
281
Expansion Valve
282
Chamber Pressure
282
Test Chamber
282
Fluid System
282
Liquid Level Measurement
282
Temperature Controlled Chamber Fluid
282
Chamber Fluid Temperature Conditioning
282
Temperature Measurement
283
Maintenance
284
Drain Pre-Saturator
284
Chamber Fluid
284
Air Input Filters (Mobile Cart)
284
Pre-Saturator Liquid Level Checkout
285
Reservoir Liquid Level Checkout
287
Warning and Error Messages
288
Saturation Temperature at Minimum Limit
288
Saturation Temperature over Range or at Maximum Limit
288
Pre-Saturation Temperature at Minimum Limit
288
Pre-Saturation Temperature over Range or at Maximum Limit
288
Expansion Valve Temperature at Minimum Limit
289
Expansion Valve Temperature over Range or at Maximum Limit
289
Chamber Temperature at Minimum Limit
289
Chamber Temperature over Range or at Maximum Limit
289
Cabinet Temperature over Range or at Minimum/Maximum Limit - Check te Fans
289
Insufficient Supply Pressure to Generate
289
Supply Pressure over Range or at Maximum Limit
289
Saturation Pressure at Minimum Limit
290
Saturation Pressure over Range or at Maximum Limit
290
Saturation Pressure Transducer Not Responding - Check USB Connection
290
Chamber Pressure at Minimum Limit
290
Chamber Pressure over Range or at Maximum Limit
290
Chamber Pressure Transducer Not Responding - Check USB Connection
290
Mass Flow Rate at Minimum Limit
290
Mass Flow Rate over Range or at Maximum Limit
290
Thermoelectric Controller Not Responding
290
Thermoelectric Controller Reported Critical Error
291
Thermoelectric Controller Temperature out of Range - Check Fans
291
Thermoelectric Controller Voltage out of Range - Check Power Supplies
291
Thermoelectric Controller High Current Condition
291
Flow Valve Reported Error
291
Flow Valve Failed to Find Home Position
291
Flow Valve at Minimum Limit
291
Flow Valve at Maximum Limit - Check Supply Pressure And/Or Reduce Flow Rate
291
Expansion Valve Reported Error
291
Expansion Valve Failed to Find Home Position
291
Expansion Valve at Minimum Limit - Check for Air Leaks
292
Expansion Valve at Maximum Limit - Reduce Mass Flow Rate
292
Distilled Water Reservoir Is Empty
292
Distilled Water Reservoir Is Low
292
Unable to Fill Pre-Saturator
292
No Saturation Fluid Temperature Change - Possible Thermoelectric Failure
292
No Pre-Saturator Heat
292
No Expansion Valve Heat
292
System Failed to Vent Pressure on Shutdown
292
Mass Flow Rate Is Being Limited to Achieve Humidity Setpoint
293
Insufficient Supply Pressure to Reach Setpoint
293
Saturation Pressure Setpoint at Minimum - Check Humidity Setpoint
293
Drawings and Diagrams
294
1220D901-1 - Part List
295
1220D901-2 - 1220 Components
296
1220D901-3 - 1220 Components (Back)
297
1220D901-4 - 1220 Components (Top)
298
1220D901-5 - Pneumatic Schematic
299
1220D901-6 - Fluid Schematic
300
1220D901-7 - Pneumatic Components
301
1220D901-8 - Electrical Components
302
1220D901-9 - Data Acq. Components
303
1220D905-1 - Chamber Fluid Filling Instructions
304
1220D905-2 - Chamber Fluid Draining Instructions
305
1220D906-1 - Cart / ACS Assembly
306
1220D906-2 - Exhaust Hose Assembly
307
1220D906-3 - Filter / Regulator Assembly
308
1220D906-4 - Cart Pneumatic System Schematic
309
1220S907 - AC / DC Power Distribution
310
1220S908 - Temperature Probe Schematic
311
1220S909 - Stepper Drive Schematic
312
1220S910 - Transducer Schematic
313
1220S911 - Exp. Valve / Pre Sat. Schematic
314
1220S912 - Solid State Relay Schematic
315
1220S913 - Cable Connections
316
1220D914 - Cart Dimensional Drawing
317
1220D915 - Probe Install Diagram
318
Advertisement
Thunder Scientific 1220 Quick Start Manual (35 pages)
Brand:
Thunder Scientific
| Category:
Measuring Instruments
| Size: 14 MB
Table of Contents
Important Notice
3
Table of Contents
7
Getting Started
8
About
8
Notice
9
Safety Information
9
Live Power Source
9
Electrostatic Discharge
9
Compressed Gas
9
Personal Protective Equipment
9
Safety Symbols
10
Technical Support
10
License Agreement
10
Warranty
12
Copyright
12
Trademarks
12
Specifications
13
Uncertainty
14
Facility Requirements
15
Environment
15
Floor or Bench Space
15
Air Supply
15
Reservoir Distilled Water Supply
15
Installation
16
Uncrating
16
Positioning
16
Chamber Fluid
16
Reservoir Initial Filling Procedure
17
Setting Supply Pressure Regulator
17
Quick Start
18
Power-Up
18
Loading Screen
19
Controlog Screen
20
Control Parameters
21
Control Modes
25
Generating and Shutting down
26
Power-Off
27
Date and Time or Point Time
28
Set Date and Time
28
Help
29
Advertisement
Related Products
THUNDER SCIENTIFIC 5A-1MP
Thunder Scientific Categories
Air Compressor
Portable Generator
Measuring Instruments
Stud Sensor
Inverter
More Thunder Scientific Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL