Sign In
Upload
Manuals
Brands
Teledyne Manuals
Digital Camera
XF-1024F
Teledyne XF-1024F Manuals
Manuals and User Guides for Teledyne XF-1024F. We have
1
Teledyne XF-1024F manual available for free PDF download: System Manual
Teledyne XF-1024F System Manual (116 pages)
X-Ray
Brand:
Teledyne
| Category:
Digital Camera
| Size: 4.63 MB
Table of Contents
Table of Contents
3
Chapter 1 Introduction
9
Low-Noise Configurations
9
Shuttering and Synchronization
9
When Flexibility Counts
9
Beryllium Warnings
10
Environmental Conditions
10
Precautions
10
Software Solutions
10
1.10 Conventions Used in this Document
11
Cleaning
11
Camera
11
Beryllium Window
11
Table 1-1: Terminology Conventions Used
11
Document Organization
12
1.12 Safety Related Symbols Used in this Manual
13
Fiberoptic Expertise
9
Chapter 2 PIXIS-XF Camera System
15
Figure 2-2: Typical PIXIS-XF Camera
16
PIXIS-XF Rear-Panel Connectors and Indicators
18
Figure 2-3: PIXIS-XF Rear-Panel Connectors
18
Table 2-1: PIXIS-XF Rear-Panel Connectors and Indicators
18
PIXIS-XF Power Supply (Air/Liquid-Cooled Systems)
19
Coolant Hoses
19
Cables
20
PIXIS-XF Camera
16
Certificate of Performance
20
User Manuals
20
Application Software
21
Accessories
22
Fiber Optic Extender
22
Coolcube II with PIXIS-XF-Compatible Hoses
22
Chapter 3 Initial System Verification
23
Table 3-1: PIXIS-XF Installation Actions
23
Figure 3-1: Block Diagram: Typical Air-Cooled PIXIS-XF System
24
System Block Diagrams
24
Figure 3-2: Block Diagram: Typical Liquid-Cooled PIXIS-XF System
25
Chapter 4 System Setup
27
Unpack the System
27
System Requirements
28
Verify Equipment and Parts Inventory
28
Install the Application Software
30
Install Winx/32
30
Figure 4-1: Typical Winview Installation Dialog: Select Installation Type
30
Install Lightfield
31
Figure 4-2: Typical Lightfield Installation Wizard Dialog
31
Table 4-1: USB Driver Files and Locations
31
Figure 4-3: Typical Coolcube II
32
Make Camera-Circulator Connections for a Coolcube
32
Configure Default Camera System Parameters
33
Configure Default Winx/32 Parameters
33
Figure 4-4: Typical Winx/32 Camera Detection Wizard: Welcome Dialog
33
Configure Default Lightfield Parameters
34
Figure 4-5: Typical Lightfield Experiment Workspace
34
Connect an External Shutter
35
Connect/Disconnect the PIXIS-XF USB Cable
35
Chapter 5 Operation
37
System On/Off Sequences
38
Winx/32 First Light
39
Figure 5-2: Typical Winview/32 First Light Acquired Data
41
Figure 5-3: Typical Lightfield Available Devices Area
42
Lightfield First Light
42
Figure 5-4: Typical Lightfield Experiment Devices Area
43
Figure 5-5: Typical Lightfield View Area
44
Figure 5-6: Typical Lightfield View Area Displaying an Image
44
Exposure and Signal
45
CCD Array Architecture
45
Exposure Time
45
CCD Temperature
46
Figure 5-7: Typical Winx Detector Temperature Dialog
46
Dark Charge
47
Saturation
47
Readout
48
Full Frame Readout
48
Figure 5-8: Array Terms for a CCD with a Dual Output Amplifier
48
Binning
49
Figure 5-9: Full Frame at Full Resolution
49
Figure 5-10: Diagram of 2 X 2 Binning
50
Hardware Binning
50
Software Binning
51
Output Amplifier {Quality} Selection
52
Figure 5-11: Array Terms for a CCD with a Dual Output Amplifier
52
Controller Gain
53
Table 5-1: Typical Controller Gain {Analog Gain} Vs. Readout Port
53
Digitization (Rate)
54
ADC Offset (Bias)
55
Chapter 6 Advanced Topics
57
Table 6-1: Camera Timing Modes
58
Free Run {No Response
59
Figure 6-1: High-Level Block Diagram: Free Run {No Response
59
Figure 6-2: Timing Diagram: Free Run {No Response
59
External Sync {Readout Per Trigger
60
Figure 6-3: High-Level Block Diagram: External Sync, Shutter Preopen Vs
60
Figure 6-4: Timing Diagram: External Sync Mode (+ Edge Trigger)
61
External Sync with Continuous Cleans {Clean until
62
Trigger} Timing
62
Figure 6-5: High-Level Block Diagram: Continuous Cleans {Clean until
62
Figure 6-6: Timing Diagram: Winx/32 Continuous Cleans
63
Figure 6-7: Timing Diagram: Lightfield Clean until Trigger
63
EXT SYNC Trigger Input
64
Figure 6-8: Rear View of PIXIS-XF Camera
64
Timing Modes
58
Fast and Safe Modes
65
Fast Mode (Winx/32 and Lightfield)
65
Safe Mode (Winx/32)
65
Figure 6-9: Flowcharts Comparing Safe and Fast Mode Operation
66
Figure 6-10: Timing Diagram: LOGIC out Control Signals
67
LOGIC out Control
67
Figure 6-11: High-Level Diagram: Kinetics Readout
68
Figure 6-12: Typical Winx/32 Hardware Setup Dialog
69
Figure 6-13: Typical Winx/32 Experiment Setup Dialog
69
Figure 6-14: Typical Lightfield Readout Expander: Kinetics Mode
70
Figure 6-15: Typical Lightfield Shutter and Trigger Expanders: Normal, no
70
Free Run (Non-Triggered Mode)
70
Figure 6-16: Timing Diagram: Free Run
71
Figure 6-17: Timing Diagram: Single Trigger
71
Triggered Modes
71
Kinetic Timing Modes
69
Kinetics Mode
68
Custom Modes
72
Custom Chip
72
Figure 6-18: Timing Diagram: Multiple Trigger
72
Figure 6-19: Typical Winx/32 Hardware Setup Dialog: Custom Chip Tab
73
Software Settings
73
Custom Timing
74
Figure 6-20: Typical Lightfield Custom Sensor Pane
74
Figure 6-21: Typical Lightfield Custom Timing Dialog
75
Figure 6-22: Typical Winx/32 Hardware Setup Dialog, Custom Timing Tab
75
Figure 2-1: Typical Air-Cooled PIXIS-XF System Components
15
Figure 5-1: Block Diagram of Light Path in System
37
Chapter 7: Troubleshooting
77
Table 7-1: List of Recommended Troubleshooting Procedures
77
Acquisition Started but Viewer Contents Do Not Update
78
Baseline Signal Suddenly Changes
78
Camera Stops Working
78
Figure 7-1: Typical Lightfield Acquisition Display
78
Camera1 (or Similar Same) in Camera Name Field
79
Figure 7-2: Camera1 in Camera Name Field
79
Figure 7-3: Editing Camera Name
79
Controller Is Not Responding
80
Figure 7-4: Camera Name on Hardware Setup Dialog
80
Coolcube II : Low Coolant (Air in the Hoses)
81
Cooling Troubleshooting
81
Temperature Lock Cannot be Achieved or Maintained
81
Camera Loses Temperature Lock
82
Gradual Deterioration of Cooling Capability
82
Data Loss or Serial Violation
82
Data Overrun Due to Hardware Conflict Message
83
7.10 Data Overrun Has Occurred Message
83
Device Is Not Found
84
Figure 7-6: Typical Lightfield Devices Missing Dialog
84
7.12 Device Is Occupied
85
7.13 Error Creating Controller Message
85
Figure 7-7: Typical Lightfield Occupied Device Icon
85
Figure 7-8: Typical Winspec/32 Error Creating Controller Dialog
85
7.14 Program Error Message
86
7.15 Serial Violations Have Occurred. Check Interface Cable
86
Figure 7-9: Typical Winspec/32 Program Error Dialog
86
Figure 7-10: Typical Winspec/32 Serial Violations Have Occurred Dialog
86
Appendix A: Technical Specifications
89
CCD Arrays
89
Camera
89
Options
91
Table A-2: Typical Deepest Operating Temperature
91
Appendix B: Outline Drawings
93
PIXIS-XF (Air-Cooled)
93
Figure B-1: Outline Drawing: Air-Cooled PIXIS-XF: 1024F/B
93
Figure B-2: Outline Drawing: Air-Cooled PIXIS-XF: 1024F/B
94
Figure B-3: Outline Drawing: Air-Cooled PIXIS-XF: 2048F/B
95
Figure B-4: Outline Drawing: Air-Cooled PIXIS-XF: 2048F/B
96
PIXIS-XF (Liquid-Cooled)
97
Figure B-5: Outline Drawing: Liquid-Cooled PIXIS-XF: 1024F/B
97
Figure B-6: Outline Drawing: Liquid-Cooled PIXIS-XF: 1024F/B
98
Figure B-7: Outline Drawing: Liquid-Cooled PIXIS-XF: 2048F/B
99
Figure B-8: Outline Drawing: Liquid-Cooled PIXIS-XF: 2048F/B
100
Coolcube II Circulator
101
Figure B-9: Outline Drawing: Coolcube II Circulator
101
Appendix C: Gd 2 O 2 S Phosphor Replacement
103
Required Items
103
Remove the Beryllium Window Assembly
103
Figure C-1: PIXIS-XF:1024 Phosphor Assembly Drawing
104
Remove and Replace the Phosphor
105
Install the Beryllium Window Assembly
105
Appendix C: Gd O S Phosphor Replacement
107
Appendix D: Winspec/32/Lightfield Cross Reference
107
Winspec/32-To-Lightfield Terminology
107
Table D-1: Winspec/32-To-Lightfield Cross Reference
107
Lightfield to Winspec/32
109
Table D-2: Lightfield-To-Winspec/32 Cross Reference
109
Warranty and Service
111
Limited Warranty
111
Basic Limited One (1) Year Warranty
111
Limited One (1) Year Warranty on Refurbished or Discontinued
111
Products
111
XP Vacuum Chamber Limited Lifetime Warranty
111
Sealed Chamber Integrity Limited 12 Month Warranty
112
Vacuum Integrity Limited 12 Month Warranty
112
Image Intensifier Detector Limited One Year Warranty
112
X-Ray Detector Limited One Year Warranty
112
Software Limited Warranty
112
Owner's Manual and Troubleshooting
113
Your Responsibility
113
Contact Information
114
Advertisement
Advertisement
Related Products
Teledyne XF-1024B
Teledyne XF-2048F
Teledyne XF-2048B
Teledyne XTRX500
Teledyne 12M
Teledyne 4M
Teledyne 89829-0201
Teledyne 89851-0201
Teledyne 89895-0201
Teledyne 89929-0201
Teledyne Categories
Measuring Instruments
Analytical Instruments
Digital Camera
Test Equipment
Security Camera
More Teledyne Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL