Manuals and User Guides for Teledyne Analytical Instruments 7500ZB. We have
1
Teledyne Analytical Instruments 7500ZB manual available for free PDF download: Operating Instructions Manual
Teledyne Analytical Instruments 7500ZB Operating Instructions Manual (128 pages)
NDIR Infrared Gas Analyzer
Brand:
Teledyne Analytical Instruments
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Safety Messages
5
Additional Caution on Safety
7
Table of Contents
11
List of Figures
15
List of Tables
16
Introduction
19
Overview
19
Figure 1-1: Model 7500ZB
19
Typical Applications
20
Items Included with the Analyzer
21
Confirmation of Delivered Items
21
Name and Description of Analyzer
22
Figure 2-1: Model 7500ZB Front Panel
22
Figure 2-2: Electrical Feedthroughs on the Model 7500ZB
23
Figure 2-3: Terminal Connections for Model 7500ZB
23
Installation
25
Installation Conditions
26
Installation
26
Installation of Analyzer Enclosure
26
Figure 3-1: Analyzer Dimensions
27
Piping
28
Figure 3-2: Gas Connections
28
Sampling
30
Sample Gas Conditioning
30
Figure 3-3: Internal Piping for the Model 7500ZB
30
Sample Gas Flow
31
Preparation of Standard Gas
31
Internal Purging of the Instrument Housing
32
Pressure at Sample Outlet
32
Example Configuration of Sample System
32
Electrical Connections
33
Operation
43
Preparation for Operation
43
Warm-Up Operation and Normal Operation
43
Display and Operation Panels
45
Front Panel Description
45
Overview of Display and Operation Panels
46
Outline of Display Screen
47
Basic Operation
51
Settings and Calibration
53
Range
53
Setting the Range Mode
53
Manual Range Mode
54
Range Identification Contacts
54
Calibration Setting
55
Setting the Span Gas Concentration
55
Manual Zero Calibration
56
Setting the Calibration Range
58
Setting the Component/Range for Auto Calibration
60
Alarm Setting
62
Setting Alarm Parameters
62
Hysteresis Setting
64
Peak Alarm Setting
65
Setting up the Auto Calibration
67
Auto Calibration
67
Forced Run/Stop of Auto Calibration
70
Execution of Auto Calibration Only Once
70
Forced Stop of Auto Calibration
71
Setting Auto Zero Calibration
73
Auto Zero Calibration
73
Forced Run/Stop of Auto Zero Calibration
75
Execution of Auto Zero Calibration (Only Once)
76
Forced Stop of Auto Zero Calibration
76
Parameter Setting
78
Maintenance Mode
86
Sensor Input Value Screen
86
Error Log Screen
86
Calibration Log Screen
87
Output Adjustment Screen
88
Other Parameter
89
Calibration
91
Zero Calibration
91
Span Calibration
92
Maintenance
93
Daily Check
93
Daily Check and Maintenance Procedures
94
Long Term Maintenance
94
Cleaning the Sample Cell
96
Sample Cell Disassembly
96
Pipe Cell Removal (See Fig. 7-1)
96
Block Cell Removal (See Fig. 7-2)
97
Figure 7-1: Measuring Unit Configuration (Pipe Cell)
97
Figure 7-2: Measuring Unit Configuration (Block Cell)
99
Removing the Measuring Unit
100
Cleaning the Sample Cell
100
Fuse Replacement
102
Error Messages
103
Troubleshooting
104
Error Log File
105
Specifications
107
General Specifications
107
Standard Specifications
107
Standard Functions
111
Optional Functions
112
Performance
116
EC Directive Compliance
116
Requirements for Sample Gas
117
Installation Requirements
118
Advertisement
Advertisement
Related Products
Teledyne Analytical Instruments 7500ZA
Teledyne Analytical Instruments 7600ZA
Teledyne Analytical Instruments 3000RS-T
Teledyne Analytical Instruments 3020 M
Teledyne Analytical Instruments 3020 P
Teledyne Analytical Instruments 4060TCD