Sign In
Upload
Manuals
Brands
Tektronix Manuals
Portable Generator
071-1609-02
Tektronix 071-1609-02 Manuals
Manuals and User Guides for Tektronix 071-1609-02. We have
1
Tektronix 071-1609-02 manual available for free PDF download: User Manual
Tektronix 071-1609-02 User Manual (196 pages)
Data Timing Generators
Brand:
Tektronix
| Category:
Portable Generator
| Size: 2 MB
Table of Contents
Table of Contents
11
Table 1-1: Comparison between the Data Generator Mode and Pulse Generator Mode
23
Figure 1-1: Channels, Groups, Blocks and Channel Assignment
25
Table 1-2: the Number of Available Physical Channels
26
Figure 1-2: Concept of Data and Window
28
Figure 1-3: Channel Assignment
29
Figure 1-4: Channel Group Window
30
Figure 1-5: Data-Listing Window and Data-Waveform Window
35
Figure 1-6: Area
36
Table 1-3: Edited Area
36
Figure 1-7: Selection of Edited Area (View by Channel)
37
Figure 1-8: Move Cursor to Dialog Box
38
Figure 1-9: Move Marker to Dialog Box
39
Figure 1-10: View with Timing
41
Figure 1-11: Data-Listing Window Properties
42
Figure 1-12: Data-Waveform Window Properties
42
Figure 1-13: Mirror Operation
43
Figure 1-14: Predefined Pattern Dialog Box
44
Figure 1-15: Step and Skip
45
Table 1-4: Predefined Pattern Settings
45
Figure 1-16: Predefined Patterns
46
Figure 1-17: User Defined Patterns Dialog Box
47
Figure 1-18: PRBS/PRWS Dialog Box
48
Figure 1-19: Shift Register Generator Representation Example
48
Table 1-5: PRBS/PRWS Dialog Box Settings
49
Figure 1-20: Import Dialog Box
51
Figure 1-21: AWG File Import Dialog Box
52
Table 1-6: AWG File Import Dialog Box Settings
52
Figure 1-22: TLA Data Exchange Format Example
54
Figure 1-23: HFS Vector File (*.Vca) Example
56
Figure 1-24: Timing Window (Data Generator Mode)
59
Figure 1-25: Data Format
60
Figure 1-26: Clock Source in Time Base Window
61
Table 1-7: Clock Source
61
Figure 1-27: Selecting a Clock Source
62
Table 1-8: Valid Frequency Range and Step Size by Clock Source (Data Generator Mode)
63
Table 1-10: Restrictions on Using External Clock Input
66
Table 1-11: Restrictions on Using External PLL Input
67
Figure 1-28: PLL Clock Multiple Rate
69
Figure 1-29: Rates and Frequencies
69
Figure 1-30: Definition of Pulse Parameters
70
Table 1-12: Pulse Parameters
70
Table 1-13: Valid Ranges of Delay Offset
71
Figure 1-31: Definition of Pulse Parameters
72
Table 1-14: Valid Ranges of Lead Delay
73
Table 1-15: Valid Ranges of Trail Delay
74
Figure 1-32: Slew Rate
76
Table 1-16: Slew Rate Control
76
Figure 1-33: Cross Point Control
77
Table 1-17: Cross Point Control
77
Figure 1-34: Writing the Pattern into the Memory While Displacing It
78
Figure 1-35: Enlarging the Clock Pattern and Speeding up the Hardware Clock
79
Figure 1-36: Obtaining a Long Delay
79
Table 1-18: Characteristics of Long Delay
80
Table 1-19: Clock Range if the Pattern Contains Only NRZ
81
Table 1-20: Clock Range if the Pattern Includes RZ or R1
82
Table 1-21: Clock Range Used Internally in Pulse Generator Mode
83
Figure 1-38: Channel Addition
86
Figure 1-39: Jitter Range of the DTGM32
87
Figure 1-40: Level Window (Data Generator Mode)
89
Figure 1-41: Output Level, Termination Resistor, Termination Voltage
90
Table 1-22: Range of Output Level Parameters
90
Figure 1-42: Jumpers on the DTGM21
94
Table 1-23: Predefined Output Levels
96
Figure 1-43: DC Output Pin Assignments
97
Figure 1-44: DC Output Window
97
Table 1-24: Predefined DC Levels
99
Clock Source (Pulse Generator Mode)
99
Figure 1-45: Trigger Parameters
101
Figure 1-46: Time Base Window (Data Generator Mode)
102
Table 1-25: Trigger Parameters on Time Base Window
102
Figure 1-47: the Procedure of Sequence Creation
104
Table 1-26: Differences between Hardware and Software Sequencers
105
Table 1-27: Jump Modes
106
Table 1-28: Jump Timing
106
Figure 1-48: Sequence Window
107
Table 1-29: Setup Items for Sequence Window
107
Table 1-31: Jitter Generation Window Settings
116
Table 1-32: Maximum Jitter Amplitude
118
Table 1-33: External Jitter
119
Table 1-34: Setting for DTG5000 Configuration Utility in Online Mode
123
Table 1-35: Setting for DTG5000 Configuration Utility in Offline Mode
124
Table 1-36: Comparison between the Data Generator Mode and Pulse Generator Mode
138
Table 1-37: Setup Items for Time Base Window
139
Table 1-38: Setup Items for Level Window
141
Table 1-39: Setup Items for Timing Window
142
Table 1-40: Valid Frequency Range and Step Size by
144
Table 1-41: Setup Items for DC Output Window
145
Advertisement
Advertisement
Related Products
Tektronix 067-1049-00
Tektronix 067-1056-00
Tektronix 070-8667-04
Tektronix 067-0885-00
Tektronix 071-1238-00
Tektronix 071-1235-01
Tektronix 071-0130-00
Tektronix 071-0833-02
Tektronix 071-0957-03
Tektronix 071-0566-03
Tektronix Categories
Test Equipment
Measuring Instruments
Amplifier
Portable Generator
Printer
More Tektronix Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL