Systec Controls deltawaveC-P manuals available for free PDF download: Manual, User Manual
Systec Controls deltawaveC-P Manual (120 pages)
Ultrasonic flow and heat measurement portable, Stationary
Brand:
Systec Controls
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
2
Table of Content
2
Preamble
5
About this Manual
6
Deltawavec-F/P & Components
7
Approvals / EMC
7
Scope of Delivery Deltawavec-F / P Basic Package
8
Transducer
9
Safety Instructions
10
Important Instructions for the Use of Deltawavec-P
10
Measuring Principle
11
2-Channel Device Applications
13
Deltawavec-F/P Interfaces
14
Overview Deltawavec-P
14
Overview Deltawavec-F
15
Connection Notes
16
Operating
17
Control Buttons
17
How to Navigate
17
Select Measurement Channel
17
First Start
18
Adjustment of the Display Language
18
Navigation in Main Menu
18
Setting Time and Date
19
Preparing for Measurement Deltawavec-F/P
20
Preparation of the Measurement / Installation Location
21
Inlet and Outlet Distances
21
Basic Principles for Ultrasonic Transducer Assembly
22
Ultrasonic Sensor Mounting on Horizontal Pipelines
23
Ultrasonic Transducer on Uneven Surfaces
24
Fundamentals of Parameterization
24
Parameterization with the Quick Setup
26
Sensor Assembly / Sensor Distance
28
Structure of Ultrasonic Transducers
28
Mounting Ultrasonic Transducer
29
Selection of Transducer Types
30
Selection of Mounting Options
30
Selection Mounting Rail
31
Selection Coupling Media
32
Transducer Mounting
33
Mounting of the Transducer in V-Mode or W-Mode
33
Mounting Permanently Installed
35
Mounting Portable
36
Mounting the Ultrasonic Transducers Based on the Z Method
38
Mounting Transducer with Two Mounting Rails
40
Mounting Z-Mode with Two Rails
40
Mounting at Large Distances
41
Mounting the Ultrasonic Transducers at Two Crossed Measuring Paths
42
Alternative Sensor Distance
42
Zero Setting
43
Signal Optimisation
45
Open Signal Optimisation
45
Functionality Signal Optimisation
45
Gain-Optimization
46
Zero-Optimization
46
Heat Measurement
47
Introduction
47
Installing the Pt100
48
Parameterization of the Pt100 for the Heat Quantity Measurement
49
Measuring Windows Deltawavec-F/P
50
Headline
50
Measuring Window "Flow 1
51
Measuring Window "Flow 2
52
The Measuring Window "Heat Quantity
53
Password Protection
54
The Measurement Windows of the 2-Channel Deltawavec-F
55
The Main Menu (Complete Menu)
56
Loading, Saving and Managing Parameter Data
56
The Pipe Parameters
58
The Fluid Setup
59
The Transducer Setup
60
Parameterization of the Inputs and Outputs
61
Parameterization of the 4-20Ma Outputs
61
Parameterization of the Relay
64
Parameterization of the Pulse Output
65
Impulse-Overflow-Error; IOE
66
Serial Communication, Modbus, MBUS & Logger
66
Serial Data Transmission
66
Modbus
68
Mbus
69
The Data Logger
70
Activation of the Data Logger
70
Administration and Structure of Log Data
71
Starting a Time-Controlled Data Record
72
Cancelling a Time-Controlled Data Record
73
Quick-Logger
74
Wakeup-Logger
74
Energy Saving Mode
75
Systems Settings
75
Editing the Time and Date
76
Changing the Indicator Light
76
Changing the Menu Language
77
System Test
77
System Information
78
System Reset
78
Unit Selection
79
Calibration
80
Flow-Offset
80
Matching the Pt100
80
Pt100 Offset
80
Parameterization of a Flow Velocity Characteristic
81
Temperature Compensation
81
Calibration of Analogue Outputs
82
Miscellaneous Parameters
83
Damping & Burnout
83
Cut off Flow
84
Zero
84
The Totalizer (Counters)
85
Pipe Roughness
86
Sensor Test
86
Additional Information about the Hardware
88
Hardware and Software Reset
88
Data Export and Import
89
Pulse Outputs Active/Passive
90
RS232 / RS485 Interfaces
91
Tips and Tricks
92
Measuring Mixed Fluids
92
Measuring Unknown Fluids
94
Troubleshooting
96
The Oscilloscope Window
97
Signal Analysis
98
Signal-To-Noise Ratio (SNR)
99
Signal Sharpness
101
Signal Decoupling on Small Pipelines
102
The Auto Window Function / AFC-Technology
103
The Diagnosis Window of the Deltawavec-F/P
105
What to Do if the Pipe Is Not Fully Filled
106
Appendix A - Material Data
107
Appendix B - Technical Data
110
Appendix C - Modbus Register Overview
112
Appendix D - Transducer Type Overview
114
Appendix E - Mounting Equipment and Accessories
116
Advertisement
Systec Controls deltawaveC-P User Manual (119 pages)
Ultrasonic flow and heat measurement portable / stationary
Brand:
Systec Controls
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
2
Table of Content
2
1 Preamble
5
2 About this Manual
6
3 Deltawavec-F/P & Components
7
Approvals / EMC
7
Scope of Delivery Deltawavec-F / P Basic Package
8
Transducer
9
Safety Instructions
10
Important Instructions for the Use of Deltawavec-P
10
4 Measuring Principle
11
2-Channel Device Applications
13
5 Deltawavec-F/P Interfaces
14
Overview Deltawavec-P
14
Overview Deltawavec-F
15
Connection Notes
16
6 Operating
17
Control Buttons
17
How to Navigate
17
Select Measurement Channel
17
7 First Start
18
Adjustment of the Display Language
18
Navigation in Main Menu
19
Setting Time and Date
20
8 Preparing for Measurement Deltawavec-F/P
21
Preparation of the Measurement / Installation Location
21
Inlet and Outlet Distances
21
Basic Principles for Ultrasonic Transducer Assembly
23
Ultrasonic Sensor Mounting on Horizontal Pipelines
23
Ultrasonic Transducer on Uneven Surfaces
24
Fundamentals of Parameterization
25
Parameterization with the Quick Setup
26
Sensor Assembly / Sensor Distance
33
Introduction to the Installation of Ultrasonic Transducers
33
Mounting Ultrasonic Transducer
34
Correct Selection of Transducer Types
35
Correct Selection of Mounting Options
35
Mounting of the Transducer in V-Mode or W-Mode
36
Mounting the Ultrasonic Transducers Based on the Z Method
38
Mounting the Ultrasonic Transducers at Two Crossed Measuring Paths
40
Zero Setting
41
9 Heat Measurement
42
Introduction
43
Installing the Pt100
44
Parameterization of the Pt100 for the Heat Quantity Measurement
45
10 Measuring Windows Deltawavec-F/P
46
Headline
46
Measuring Window "Flow 1
47
Measuring Window "Flow 2
48
The Measuring Window "Heat Quantity
49
Password Protection
50
The Measurement Windows of the 2-Channel Deltawavec-F
51
11 The Main Menu (Complete Menu)
52
Loading, Saving and Managing Parameter Data
52
The Pipe Parameters
54
The Fluid Setup
55
The Transducer Setup
56
Parameterization of the Inputs and Outputs
57
Parameterization of the 4-20Ma Outputs
57
Parameterization of the Relay
59
Parameterization of the Pulse Output
60
Impulse-Overflow-Error; IOE
61
Serial Communication, Modbus & Logger
61
Serial Data Transmission
61
Modbus
63
The Data Logger
64
Activation of the Data Logger Function
64
Administration and Structure of Log Data
65
Starting a Time-Controlled Data Record
65
Cancelling a Time-Controlled Data Record
67
Quick-Logger
67
Systems Settings
68
Editing the Time and Date
68
Changing the Indicator Light
68
Changing the Menu Language
69
System Test
69
System Information
70
System Reset
70
Unit Selection
71
Calibration
72
Flow-Offset
72
Matching the Pt100
72
Pt100 Offset
72
Calibration of Analogue Outputs
73
Parameterization of a Flow Velocity Characteristic
73
Miscellaneous Parameters
75
Damping & Burnout
75
Cut off Flow
76
Zero
76
The Totalizer (Counters)
76
Sensor Distance
78
12 Additional Information about the Hardware
79
Hardware and Software Reset
79
Data Export and Import
80
Parameterization of the Deltawavec-F Pulse Output Hardware
81
Operating Mode 1: High Side (PNP-Switch)
82
Operating Mode 2: LOW Side (NPN-Switch)
83
Operation Mode Push-Pull
84
RS232 / RS485 Interfaces
85
13 Tips and Tricks
87
Measuring Unknown Fluids
88
14 Troubleshooting
90
The Oscilloscope Window
91
Signal Analysis
92
Signal-To-Noise Ratio (SNR)
93
Signal Sharpness
95
Signal Decoupling on Small Pipelines
96
The Auto Window Function / AFC-Technology
97
The Diagnose Window of the Deltawavec-F/P
99
Integrated Sensor Test Function
100
What to Do if the Pipe Is Not Fully Filled
101
Checklist
102
Appendix A - Material Data
105
Appendix B - Technical Data
108
Appendix C - Modbus Register Overview
110
Appendix D - Transducer Type Overview
112
Appendix E - Mounting Equipment and Accessories
114
Advertisement
Related Products
Systec Controls deltawaveC-F
Systec Controls deltawaveCoG-F
Systec Controls deltawaveCoG-P
Systec Controls deltawaveCoG
Systec Controls Categories
Measuring Instruments
More Systec Controls Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL