Sign In
Upload
Manuals
Brands
SYSMEX Manuals
Laboratory Equipment
CA-500
SYSMEX CA-500 Manuals
Manuals and User Guides for SYSMEX CA-500. We have
1
SYSMEX CA-500 manual available for free PDF download: Service Manual
SYSMEX CA-500 Service Manual (259 pages)
Automated Blood Coagulation Analyzer
Brand:
SYSMEX
| Category:
Laboratory Equipment
| Size: 4.48 MB
Table of Contents
To Cover Section 1 Specifications
3
Table of Contents
3
Section 1 Specifications
4
Outline
4
Name and Model
4
Configuration and Dimensions
4
Configuration and Expandability of the System
4
Power Source
5
Dimensions and Weight
5
Each Unit Function and Operation
5
Principles of Measurement
6
Performance, Intended Use and Effectiveness
6
Intended Use
6
Performance
6
Functions
12
Acoustic Noise Level
16
Environmental Conditions
17
Operating Environment
17
Reagents to be Used
17
How to Operate
18
Section 2 Hydraulic/Mechanical Systems
19
Tubing Diagram
20
Hydraulic System Operation
21
Structure
21
Operation
21
Pressure Circuit
23
Structure
23
Operation
23
Detector Block
24
Outline
24
Specifications/Functions
24
Assembly Diagram
24
Reagent Cooling Unit
25
Outline
25
Specifications/Functions
25
Assembly Diagram
25
Volumetric Unit
26
Outline
27
Specifications/Functions
27
Assembly Diagram
27
X-Y Drive Unit (X-Axis Motor Assembly/Drive-Axis Arm Assembly)
27
Outline
28
Specifications/Functions
28
Assembly Diagram
28
Z-Axis Drive Unit (Z-Axis Base Assembly)
28
Bar Code Reader Unit (ID Completed Parts)
29
Outline
29
Specifications/Functions
29
Pump Unit (Pressure Pump/Vacuum Pump Completed Parts)
30
Outline
30
Specifications/Functions
30
Assembly Diagram
30
Section 3 Electronics to Cover
31
PCB Locations
32
Section 3 Electronics
32
Block Diagram and Power Source
33
PCB No. 2132 (PD; Photo Diode, Pre-Amplifier, LED Relay)
37
PCB No. 2156 (PD2; Photo Diode, Pre-Amplifier, LED Relay)
37
PCB No. 2133 (THERMO; Thermister)
39
PCB No. 2134
39
Y-Axis Home Position Sensor, Z-Axis Relay)
39
PCB No. 2157 (Y-Z RELAY2; Liquid Surface Sensor, Probe Crash, Y-Axis Home Position Sensor, Z-Axis Relay)
39
PCB No. 4086 (PS; Power Source, Motor Driver)
42
PCB No. 6350 (PRCN-1; Printer Control Board)
46
PCB No. 6375 (PRCN-3; Printer Control Board)
46
PCB No. 6362 (MAIN; CPU, I/O, Motor Control, Temperature Control, A/D)
47
PCB No. 6373 (MAIN-2; CPU, I/O, Motor Control, Temperature Control, A/D)
47
PCB No. 7015 (MEMORY; Program Memory)
54
PCB No. 9258 (LED2; LED for Scattered Light)
54
PCB No. 9259 (LED1; LED for Transmitted Light)
55
PCB No. 9260 (X RELAY; X-Axis Relay)
55
PCB No. 9263 (VR; LCD Contrast Volume)
56
PCB No. 9264 (Z RELAY; Z-Axis Relay, Z-Axis Home Position Sensor)
56
PCB No. 9265 (PR RELAY; Operation Panel, Syringe Motor, SV 1 Relay)
57
PCB No. 9303 (PR RELAY2; Operation Panel, Syringe Motor, SV 1 Relay)
57
To Cover Section 4 Adjustment
58
Pressure Adjustment
59
Adjustment of Pressure Detector Circuit
59
Adjustment of Pressure Indication
61
Section 4 Adjustment
59
Detector Block Sensitivity Adjustment
62
Required Tools for Adjustment
62
Overview of Adjustment Screen (Description)
62
Adjustment of Detector Well for Analyzing the Scattered Light
64
Adjustment of Detector Well for Analyzing the Transmitted Light (Chromogenic and Immunoassy)
66
Exit Adjustment
67
Target Value List for Adjustment
67
Mechanical System Adjustment
69
Required Tools for Adjustment
69
How to Enter the Mechanical System Position Adjustment Mode
69
The Mechanical System Position Adjustment Screen
70
Position Adjustment Procedure of Pipette ("[1]Blood 1", "[2]Blood 10", and "[3]Blood_Stat")
72
Position Adjustment Procedure of Pipette ("[4]Reag 1") ("[5]Reag 9") ("[6]Reag 10")
75
Position Adjustment Procedure of Pipette ("[7]Reag_Rinse") ("[8] Buffer")
76
Position Adjustment Procedure of Pipette ("[10]Wash_O)
79
Output Setting Values
89
Temperature Adjustment
90
Temperature Control Summary
90
Temperature Verification at each Unit
90
Temperature Adjustment Procedures
91
Electrical Adjustment
92
PCB No. 6362: MAIN (CPU, I/O, Motor Control, Temperature Control, A/D)
92
PCB No. 6373: MAIN-2 (CPU, I/O, Motor Control, Temperature Control, A/D)
92
PCB No. 4086: PS (Power Source, Motor Driver)
94
To Cover Section 5 Service Program
95
Section 5 Service Program
96
Service Mode
96
Starting and Quitting the Service Mode
96
Menu Structure
96
Service Setting
97
Adjust
99
Printing Adjustment Data
99
Initialize
100
Initializing Stored Data
100
Initializing QC Data
101
Initializing User Settings
101
Initializing Entire Memory
101
Initializing Service Settings
102
Data Check
102
Contents Stored in BBRAM
102
Contents Stored in EEPROM
103
Items Needing Backup When Initializing
103
Test Menu
104
Drain Liquid
104
Dispense Volume
105
Full Power
106
Reagent Temp
107
Tube Transfer Test
107
Catcher Test
108
Flag Threshold
109
Test Mode
112
Analysis Check Mode
112
Rinse Wait Time
112
Barcode Mod. 7
113
Wash Test Mode
113
ADC BUFF (for Factory Use Only)
113
Vlin Interim (for Factory Use Only)
113
Reagent Vial Setting
114
Output of Service Settings
116
LED Calibration Setting
117
Adjustment Value Calculation Method
118
Factory Setting Value Table
119
Position Adjustment
119
Detector Block Adjustment Value
120
Temperature Adjustment Value
120
Transmitted Light LED Adjustment Value
120
Pressure Adjustment Value
120
Service Setting Value
121
Test Mode Value
121
Reagent Vial Setting Value
121
LED Calibration Value
121
Analysis Protocol
122
Customer Setting Value
124
Standard Curve Settings
127
Quality Control • Setting Value
128
Settings of CA-500 with 800Nm Detector
131
To Cover Section 6 Error Message
132
Pressure Errors
136
Pressure Pump Error
136
Vacuum Pump Error
137
Section 6 Error Message
136
Temperature Errors
138
Temperature Error (High)/Incubator, Temperature Error (Low)/Incubator
138
Temperature Error (High)/Detector, Temperature Error (Low)/Detector
139
Temperature Error (High)/Cooler, Temperature Error (Low)/Cooler
140
Temperature Error (High)/Room, Temperature Error (Low)/Room
141
Temp. Sensor Error/(Position)
141
Chamber Errors
142
Waste Bottle Is Full
142
Replenish Rinse Reagent
142
Motor Errors
143
Axis Home Position Error
143
Y Axis Home Position Error
144
Z Axis Home Position Error
145
Z Axis down Error
146
Tube Catch Error (Position)
147
Tube Release Error (Position)
148
Dispensing Errors
149
No Sample (Rack Position)
149
Sampling Error (Position)
150
Insufficient Reagent (Holder No.)
151
No Reaction Tube
152
Probe Crash
153
Syringe Error
154
Check Syringe Unit
155
Sampler Errors
156
Replace Sample Rack
156
Set Sample Rack
156
Replace Sample Rack Drawer
157
Barcode Scanner Driver Error
158
Barcode Scanner Error
158
Change Sample Rack
159
Replace STAT Sample
160
Exist same Sample no
161
Load New Sample
161
Analysis Errors
162
Analysis Error
162
Check Reagent Expiry
163
Check Control Expiry
163
Memory Errors
164
Invalid Settings
164
Stored Data Error
164
QC Data Error
164
External Device Errors
165
No Paper
165
Printer Error
166
HC off Line
166
HC Communication Error
167
HC CTS Time out
167
HC ACK Code Error
167
HC Transmission Count Error
167
HC Reception Count Error
167
HC ACK Time out
168
HC STX Time out
168
HC ETX Time out
168
Instruction Not Found in HC
168
Serial Illegal Error
168
Quality Control and Standard Curve Errors
169
QC Limit Error
169
QC Limit Error (STOP)
169
Set more than Two Points
169
Standard Curve Error
170
Operation Errors
171
Interrupt by Mechanical Stop
171
Turned off During Operation
172
Light Shield Open
172
Enter Work List
173
Check Reagent Volume 1
173
Insufficient Reaction Tube
173
Others
174
Voltage Low Limit
174
CPU Failure ("Number")
175
Appendix A Parts List to Cover
178
Appendix A Parts List
179
Main Unit Chassis Assy (1/2
179
Main Unit Chassis Assy (2/2
181
Chassis Assy (1/2
183
Chassis Assy (2/2
185
Detector Block
187
Cooling Section Assy
189
Axis Slider Assy
191
Z Axis Base Assy
193
Catcher Assy
195
Pipette Holder Assy
195
Cylinder Assy
197
Volumetric Piston Assy
197
Volumetric Mech. Assy
199
Operation Panel Assy (1/2
201
Operation Panel Assy (2/2
203
Rear Panel for Bottles
205
Rinse Bottle Assy
207
Waste Bottle Assy
207
Accessories
209
CA-5H Z-Axis Position Adjustment Tool PM
209
Tubing Diagram
212
Pressure Chamber Assy
213
Panels
214
Sampler
215
Recommended Parts
217
Alphabetical Index
218
Part No. Index
224
Appendix: B Installation to Cover
230
Appendix: B Installation
233
Installation Space
233
Remove Shipping Clamps
234
Attach Trap Chamber
236
Connect Rinse Bottle and Waste Bottle
237
Connect Power Cord and Connection Cord
238
Set Print Paper
239
Adjust LCD Contrast
241
Replenish Rinse Solution
242
Set Reagent Rack and Reaction Tube Rack
244
Set Tube Trash Drawer
244
Install Sampler with ID Bar Code Scanner (Option
245
Appendix C Disassembly
252
Detector Unit Assembly
252
Cooler Unit Assembly
254
Volumetric Unit Assembly
255
Drive Arm Assembly
256
Operation Panel Assembly
259
Advertisement
Advertisement
Related Products
SYSMEX CS-5100 LAS
Sysmex CyFlow Cube 8
SYSMEX CyFlow Ploidy Analyser
SYSMEX CyFlow Space
SYSMEX CyStain VitalCount
SYSMEX KX-21
SYSMEX ogt Cytocell Multiprobe CLL
SYSMEX ogt Cytocell Multiprobe OctoChrome
SYSMEX Ploidy
SYSMEX PMP 016
SYSMEX Categories
Measuring Instruments
Laboratory Equipment
Medical Equipment
Samplers
More SYSMEX Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL